Appendix D: Advanced Information
78 Cobalt CacheRaQ 4 User Manual
1. Connect a null modem serial cable to the serial console port on the back
panel of the CacheRaQ 4. See the following gure.
2. Congure your terminal software to the following parameters:
115 200 Baud
8 data bits
no parity
1 stop bit
3. Power on the CacheRaQ 4 with the power switch on the back panel.
4. A number of boot messages are displayed on your terminal screen.
5. The rst prompt asks for an IP address. Enter the Primary IP Address for the
CacheRaQ 4 (for example, 10.9.19.55).
6. The second prompt asks for the netmask address. Enter the Primary Netmask
for the CacheRaQ 4 (for example, 255.0.0.0).
7. The third prompt asks for the gateway address. Enter the gateway for the
CacheRaQ 4 (for example, 10.9.25.254).
8. Conrm the settings that you have entered:
Primary IP Address: 10.9.19.55
Primary Netmask: 255.0.0.0
Gateway: 10.9.25.254
9. Another prompt is displayed: [S]AVE / [C]ANCEL. Enter S to save the
conguration. The message Verifying and saving... appears.
10. Once the conguration is saved, the terminal screen displays the normal boot
status messages. Continue administration of the CacheRaQ 4 through your
Web browser.
Serial
console port
Serial
port
Network
connectors