User manual

SP-5000M-CXP2 / SP-5000C-CXP2
- 35 -
Associated GenICam register
GenICam
Name
Access
Values
Category
Exposure
Auto
R/W
Off
Continuous
Once
Acquisition Control
Exposure
Auto Max
R/W
100 to
1000000
JAI-Custom
Exposure
Auto Min
R/W
100 to
1000000
JAI-Custom
7.3. Trigger Control
7.3.1 Trigger Source
The following signals can be used as the trigger source signal.
OFF
Line 5 (Input to Opt In 1 and output from Digital IO
Line 4 (Input to TTL In1 and output from Digital IO
User Out 0 to 3
Trigger Packet IN
Soft Trigger
Pulse Generator 0 to 3
NAND1/NAND2
7.3.2 Trigger activation
This command can select how to activate the trigger.
Rising Edge: At the rising edge of the pulse, the trigger is activated.
Falling Edge: At the falling edge of the pulse, the trigger is activated.
Level High: During the high level of trigger, the accumulation is activated
Level Low: During the low level of trigger, the accumulation is activated
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
Table 16 Trigger activation for each trigger mode
RisingEdge
FallingEdge
LevelHigh
LevelLow
Timed
×
×
TriggerWidth
×
×
Timed - PIV
×
×
Timed - RCT
×
×
7.3.3 Trigger Overlap
This function defines whether or not a trigger pulse can be accepted while data is being read out.
OFF The trigger pulse is not accepted during the sensor readout.
Read Out The trigger pulse can be accepted during the sensor readout.