User manual
SP-5000M-CXP2 / SP-5000C-CXP2
- 35 -
Associated GenICam register
GenICam
Name
Access
Values
Category
Exposure
Auto
R/W
Off
Continuous
Once
Acquisition Control
Exposure
Auto Max
R/W
100 to
1000000
JAI-Custom
Exposure
Auto Min
R/W
100 to
1000000
JAI-Custom
7.3. Trigger Control
7.3.1 Trigger Source
The following signals can be used as the trigger source signal.
OFF
Line 5 (Input to Opt In 1 and output from Digital IO
Line 4 (Input to TTL In1 and output from Digital IO
User Out 0 to 3
Trigger Packet IN
Soft Trigger
Pulse Generator 0 to 3
NAND1/NAND2
7.3.2 Trigger activation
This command can select how to activate the trigger.
Rising Edge: At the rising edge of the pulse, the trigger is activated.
Falling Edge: At the falling edge of the pulse, the trigger is activated.
Level High: During the high level of trigger, the accumulation is activated
Level Low: During the low level of trigger, the accumulation is activated
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
Table – 16 Trigger activation for each trigger mode
RisingEdge
FallingEdge
LevelHigh
LevelLow
Timed
○
○
×
×
TriggerWidth
×
×
○
○
Timed - PIV
○
○
×
×
Timed - RCT
○
○
×
×
7.3.3 Trigger Overlap
This function defines whether or not a trigger pulse can be accepted while data is being read out.
OFF: The trigger pulse is not accepted during the sensor readout.
Read Out: The trigger pulse can be accepted during the sensor readout.