Error Description
100, N01, CAL
Exceeded 5 degree range
between placement of calibration
weight from outside flange to
inside flange.
100, N02, CAL
Calibration wheel is more than
1-ounce out of balance. Calibration
is rejected.
100, N03, CAL
Calibration wheel is more than
0.25-ounce but less than 1-ounce
out of balance. Calibration is
stored, but with warning.
Overload Protection - The balancer’s motor is over-
load protected per UL requirements. After 4 to 5 min-
utes the machine automatically resets itself; activating
the fan motor. If this happens, notify your Certified
Service Partner immediately.
Important: Allow the fan to cool the motor for at least
30 minutes before using the balancer so the overload
protection is not tripped again.