350131 & 350132 Wireless Adjustable Base OWNER’S MANUAL Installation & Operation Serial No. Patent Pending 2-Year Parts and Labor on entire base Warranty.
CONTENTS Safety & Warranty Warnings 01 Parts List 06 350131 Electronics Quick Reference Guide 07 350132 Electronics Quick Reference Guide 09 Installation Guide 11 350131 Remote Control Instructions 13 350132 Remote Control Instructions 15 350132 Bluetooth Instructions 17 Setting Programmable Positions and Pairing Remote 18 Emergency Battery Backup 20 Synchronizing Two Bases 22 Headboard Bracket Installation Guide 24 Troubleshooting 25
Safety & Warranty Warnings Attention: Read the following information before using this product . Failure to use a surge protection device could compromise safety or cause product malfunction and could void the electrical portion of your warranty. Electrical surges are by far the biggest cause of problems with electrical circuits. In order to help protect your investment in case of a power surge or outage, use an electrical surge protection device (not included).
PACEMAKER WARNING: The massage units in this bed produce mechanical vibrations that may activate a special sensor in your pacemaker that detects motion. This can fool the pacemaker into “thinking” you are engaged in some sort of physical actvity and require a faster heart rate. You may experience a sensation similar to when you are exercising. Consult your physician for further information.
ADDITIONAL TERMS AND CONDITIONS This warranty does not apply; (a) to any damage caused by the purchaser; (b) if there has been any repair or replacement of adjustable bed parts by an unauthorized person; (c) if the adjustable bed has been mishandled (whether in transit or by other means), subjected to physical or electrical abuse or misuse, or otherwise operated in any manner inconsistent with the operation and maintenance procedures outlined in the Owner’s Manual (d) to damage to mattresses, fabric, cables
PRODUCT RATINGS: The bed lift motors are not designed for continuous use of more than 2 minutes in an 18 minutes period, or approximately 10% duty cycle. Any attempt to circumvent or exceed this rating will shorten the life expectancy of the product and may void the warranty. WEIGHT UNITS: The limitation for this adjustable bed is 850 lbs. The bed will structurally support these weights, provided weight is evenly distributed across the head and foot sections.
TO REDUCE THE RISK OF SHOCK, BURNS, FIRE OR INJURY: Make sure the base is in a flat position and the vibrating motors are turned off before unplugging the bed base from the power source. Always unplug the base from the electrical outlet before cleaning or servicing the base . If the cord or plug is damaged, discontinue use of the bed base. Contact a qualified service personnel for examination and repair. FCC COMPLIANCE: This device complies with part 15 of the FCC Rules for residential use.
Parts List All electronics and components that need to be installed are located in boxes under the foundation or attached to the frame. Before discarding the packing materials, ensure that all the parts are accounted for.
350131 Electronics Quick Reference Guide Head Motor Control Box 7-27 Foot Motor
Control Box Power Supply Pairing Button Power Cord Head Motor Foot Motor 8-27
350132 Electronics Quick Reference Guide Head Motor Control Box Foot Motor USB Ports Head Massage Motor LED Light 9-27 Foot Massage Motor
Control Box Pairing Button Power Supply Power Cord LED Light Head Motor USB Ports Foot Motor Foot Massage Motor Head Massage Motor 10-27
Installation Guide 2. To install all six legs (seven for king/CK size,see image A on page 12) , thread the bolt of the leg to the nut on the foundation frame, and tighten by hand. DO NOT OVERTIGHTEN. Two people are required to set up the foundation. NOTE: To avoid damage to the foundation, always open the carton while the bed is in the flat position. 3. Uncoil the input power cord (connected to the control box’s power port) and plug it into the power supply. 1.
5. Carefully flip the foundation over onto its legs. A Middle Leg on King/CK Size Only Head Important: Two people are required to move the foundation. Do not drag across the floor. Do not rest frame on its side; excessive pressure may damage the legs. Leg Positions 6. Ensure that batteries are correctly installed. 7. Locate the mattress retainer bar brackets. Slide the left side of the mattress retainer bar into the bracket. Pull the retainer bar to the opposite bracket and secure the right side.
350131 Remote Control Instructions Zero G Preset Position Anti Snore Preset Position Lifts and Lowers Head Lifts and Lowers Foot Flat Position Flashlight Memory Position 13-27
ADJUST ONE TOUCH BUTTONS One touch FLAT preset position The HEAD arrows lift and lower the head section of the foundation. Flashlight One touch ZG preset position The FOOT arrows lift and lower the foot section of the foundation.
350132 Remote Control Instructions Zero-G Preset Position Anti Snore Preset Position Lifts and Lowers Head Lifts and Lowers Foot Flat Position Memory Position Flashlight Head Massage ON (3 intensities) Foot Massage ON (3 intensities) Massage Modes Select (3 modes) Remote Lock/Unlock Under Bed LED ON/OFF Massage ON/OFF 15-27
ADJUST ONE TOUCH BUTTONS MASSAGE FEATURE One touch FLAT preset position. Head Massage ON (3 intensities) One touch ZG preset position Foot Massage ON (3 intensities) One touch programmable preset position.
350132 Bluetooth Instructions Step 1: Plug base into power source. Step 2: Turn Bluetooth on in cell phone. For IOS System Step 3: Install the app. For Android System 1.Go to APP Store. 2. Type "Coaster sleep" into search field and install app as shown below. 1. Go to Google Play Store. 2. Type "Coster sleep" into search field and install app as shown below . Step 4: Control device via app. 1.Open Coaster Sleep app. 2. Refresh list and select your device as shown in picture below. 3.
Setting Programmable Positions and Pairing Remote SETTING PROGRAMMABLE POSITIONS The adjustable bed base has a programmable feature that allows you to save custom positions. Please read all the instructions below before setting your custom presets on the remote. STEP 1 Adjust the head and foot to your desired position. STEP 2 Press and hold the flat button first, then press and hold memory button for 5 seconds until you hear 2 beeps sound.
PAIRING REMOTE The original remote that comes in the box is already paired to the foundation. No further action is required. In the event that the remote is not paired with the foundation, follow the steps below. STEP 1 Insert batteries . STEP 2 Plug power cord into a power source. STEP 3 Press and hold head lift and foot lift simultaneously, then press and hold the button located on the pairing module connected to the control box for 3 seconds. Once you hear 2 beeps, your remote is now paired.
Emergency Battery Backup Overview Important: The backup battery is only to be used in case of a power outage. Batteries are not to be used for normal operation of the bed. The backup battery will not support repeated movement for an extended period of time. Backup Battery Use: Use two 9V batteries only (not included). If a power outage occurs, install the 9V batteries into the power supply to allow temporary power to the base (see image A).
21-27
Synchronizing Two Bases STEP 1 STEP 3 Plug A and B bases to power source. Pair remote A to Base B, then base A and base B can be simultaneous operated by Remote A. Base A Base B Base A Base B Pairing Remote A Remote A Remote B STEP 2 Make sure remote A was already paired to Base A and Remote B was paired to Base B. If not, please pair them by following the pairing remote instructions on page 19.
STEP 4 Set Remote B operate both bases too. Press and hold head down and foot down buttons on remote B, The flash light will be on for 10 seconds. Meanwhile press and hold head up and foot up buttons on Remote A, the learning process is successful when the flashlight on remote B starts to flash. Now both remotes will be able to operate both beds simultaneously.
Headboard Bracket Installation Guide Headboard brackets are an optional accessory and are not included. A 1/2'' (13 mm) socket and 1/2'' (13 mm) crescent wrench are necessary to complete installation. HEADBOARD BRACKET COMPONENTS (2) Headboard Brackets (2) T-Brackets (12) Short Bolts (12) Nuts STEP 2 STEP 1 The headboard bracket will have 2 long slots to accomodate any frame type. Align the appropriate slots on the bracket with the holes on the bed. Use bolts and nuts to secure the bracket.
Troubleshooting In the event that the power foundation fails to operate, assess the symptoms and possible solutions provided in the chart below. SYMPTOMS SOLUTIONS Remote control illuminates and appears to be operable, but will not activate bed. Verify that the power cord is plugged into a working, grounded electrical outlet. Test the outlet by plugging in another working appliance.
In the event that the power foundation fails to operate, assess the symptoms and possible solutions provided in the chart below. SYMPTOMS SOLUTIONS Check batteries in wireless remote control, replace with two (2) new AAA batteries if necessary. Head & Foot lift function has minor interference during operation. Make sure that you are following the duty cycle of the motors (do not operate more than two minutes over a 18-minute period, or approximately 10% duty cycle).
SYMPTOMS SOLUTIONS A clicking noise is heard under the bed when raising or lowering. This is normal. The lift motor relays “click” when they are engaged. No action is required. Massage motor overheats or stops. If the vibration motor overheats, the thermal protection will turn the motor off. Wait 30 minutes, turn the massage back on. If it does not come on, turn it off and report the situation to customer service.