Troubleshooting guide

SPA IS LEAKING
PUMP MOTOR DOESN’T RUN
PUMP MOTOR RUNS HOT
NOTE: These motors will feel hot to the touch. This is normal. The internal overload
protector will turn the motor off if there is an overload or high temperature problem.
MP3 PLAYER DOESN’T PLAY
TROUBLESHOOTING GUIDE
Probable Cause Recommended Action
Loose connection Hand tighten all quick disconnects and fittings, check gaskets and
o-rings.
Probable Cause Recommended Action
No power to the motor Check power switches and circuit breakers. Check motor plug into
control panel.
Blown fuse Replace pump fuse.
Thermal overload has tripped Wait until motor cools off.
Pump jammed from foreign matter in
Impeller
Call dealer for recommended action.
Motor overheats during hot days while
filtering
Reprogram your controls to cycle during the coolest parts of the
day or shorter cycles.
Probable Cause Recommended Action
Pump ran dry Call Dealer for recommended action.
Motor vent is blocked. Clear debris or obstruction to the motor vent.
Restricted suction lines Clear lines of debris.
Probable Cause Recommended Action
No power from the MP3 Player Recharge MP3 player battery.
Cable from MP3 to Adapter jack not con-
nected properly
Ensure ends are pushed all the way inside receptacle.
Speakers are under water The speaker’s performance will be affected to the degree they are
under water.
18