Service manual
24
[ Fig.8-6 ] Suction filter cleaning
8-3-5 Cleaning the Suction Filter
1) Check the contamination level every 500 hrs.
2) Replace the heavily contaminated filter even before
the replacement period.
3) Blow the element with the compressed air outward,
and then by the side.
4) Keep dust and foreign substances out of the
compressor during the assembly.
Caution
A suction filter significantly affects the service life of an airend. Make sure to use only the genuine Coaire
suction filter. Coaire cannot be responsible for any damage caused by an improper replacement.
8-3-6 Check valve
[ Fig.8-7 ] Check valve
Compressed air leakage may come from suction filter
originated form check valve leakage. In severe case, airend
Back-lash occurred. This case may cause severe damage to
airend because of foreign objects from outside. To prevent
possible defect, check valve every 2,500hours
1) Screw CAP open .
2) Check spring tension and SEAT of Check valve
3) Replace valve when it has been damaged.
Warning
Be sure of 0 psi of air pressure. It may cause injuries or severe damages
MAINTENANCE
SPRING
CAP
SEAT
VALVE BODY