Service manual

17
1) Push the “On/Off” switch into “Off”.
2) Turn the main power off.
3) Check if the internal pressure is completely discharged from the compressor.
5-2-4 Stop
5-2-5 Operation Log
Regularly record the information about the operation events in the operation log to early find the
failure of the compressor and to prevent the accident before happens. The information includes
the discharge pressure, operating time, maintenance items and the time to replace the parts.
There is a sample operation log attached in the user’s manual.
1) It is extremely hazardous to disassemble the valves or pipes from the compressor system during
the operation.
2) Always check if the pressure is 0 psi in the tank before disconnecting the valves or pipes.
3) Since the tank is still hot for a certain time even after the operation is stopped, there is a danger
of burns if you are not careful.
4) The rotating parts in the compressor is extremely dangerous during the operation. Do not come
near the parts until the compressor is stopped and the main power is turned off.
Warning
OPERATION