5-2 Routine Operation
5-2-1 Checklists before the Operation
[ Table 5-1 ] Operation Parameters
Section Model
CSOF-S3PL(H), CSOF-S5PL(H)
Setting Pressure psi 115(Low pressure) / 140(High pressure)
Differential Pressure psi
Stop : 115(Low pressure) / 140(High pressure)
Re-start : 93(Low pressure) / 120(High pressure)
High temp. stop 176 ( @ Airend )
Starting Method
D.O.L
1) Connect the main power
2) Push the “On/Off” switch into “On” and check the compressor is well started up, and the indicator lamp
are normally on.
3) Check if there is any abnormal vibration, noise and leakage
5-2-2 Start-Up
1) Check if the tank pressure is 0 Mpa.
2) Open air outlet valve when the compressor condition is normal and then push the “On/Off” switch
into “On” to start-up the unit.
3) Check if there is any abnormal noise, and the operation is in good condition.
5-2-3 During the Operation
1) With a full load, check the lamp of control panel.
2) Pull the ring on the safety valve every 500 hours to check if the operation is normal.
Item Regulation Re-mark
Airend Temp. Max. 176℉(@Airend)
Amb. Temp 32~104℉
Lamp on during the operation Power, Run
Lamp on high temp. or
temp. sensor is disconnected.
Alarm
Flikering lamp when OCR is operated. Alarm
Input voltage ±5% of rated voltage
Pressure gap of unit and discharge Max. 7.25 psi
[ Table 5-2 ] Checklists During the Operation
OPERATION
Check the following conditions before starting the operation.