OILLESS SCROLL AIR COMPRESSORS MAINTENANCE MANUAL AND PARTS LIST CSOF-S3PL/H12 CSOF-S3PL/H22 CSOF-S3PL/H32 CSOF-S3PL/H42 CSOF-S5PL/H22 CSOF-S5PL/H32 CSOF-S5PL/H42 All rights reserved January, 2013 Printed in U.S.A. For proper and safe use of the compressor, please follow all instructions and safety precautions as identified in this manual, along with general safety regulations and practices.
WARRANTY STATEMENT OF WARRANTY TERMS & CONDITIONS General Provisions: a) Coaire warrants our air compressors and scroll systems (henceforth called “products”) to be free from material defects and workmanship under proper use, operating conditions, installation, and application based on the terms and conditions set forth below. Coaire offers no other warranty, whether expressed or implied, including any warranty of merchantability or fitness for a particular purpose.
CONTENTS 1.0 Table of contents 1.0 Contents -------1 7.0 2.0 Safety and warnings 2-1 General -------2 2-2 Safety caution -------2 2-3 Safety and warnings -------3 8.0 3.0 General 3-1 Specification -------4 3-2 Major component -------5 3-3 System diagram -------6 9.0 4.
SAFETY AND WARINGS 2.0 Safety and Warning 2-1 General 1) The air compressor shall only be operated by a person who has been trained in a safe operation. 2) Please read and be familiar with the user’s manual and the safety instructions before using the air compressor. 3) The scroll air compressor alone cannot be used for a respiratory system, food and medical equipment under any circumstance. 4) Do not leave inflammables and explosives near the air compressor.
SAFETY AND WARINGS 2-3 Safety and Warnings 2-3-1 CSOF-S3PL(H), CSOF-S5PL(H) DANGER Hazardous voltage inside. Shut off power. Will shock, cause injury of death. DANGER Keep hands, feet and clothing away from driven parts. Will cause injury or death. WARNING Check The Rotation [ Fig. 2-1 Iso view] WARNING Do nottouch! Hot surface. Will cause injury. [ Fig.
GENERAL 3.0 General 3-1 Specification Model CSOF-S3PL(H) Single Stage Oil Free Scroll Compressor Type Air CSOF-S5PL(H) 115 psi 8.5 14.1 140 psi 7.2 12 Belt 3V-360x2EA 3V-380x2EA Delivery UNIT (cfm) Driving Method High temp. stop (℉) 176 Output ( kW/HP ) MOTOR 2.2/3 3.7/5 Voltage ( V ) 208-230, 460 Frequency ( Hz ) 60 Poles 4 Starting Method DIRECT ON LINE Air Outlet (Inch) 1/2” Receiver Tank (gal) Over 10 (Option) Cooling Type Air Cooled Service air temp.
GENERAL 3-2 Major component 3-2-1 CSOF-S3PL(H), CSOF-S5PL(H) #. DESCRIPTION 1. COMMON BASE 19 17 2. COVER & FRAME 18 4 11 3. AIREND 4. MOTOR 5. MOTOR PULLEY 5 6. AIREND PULLEY 13 7. SUCTION FILTER 8. MANIFOLD 9. AIR COOLER 12 10. VENTILATION FAN 6 11. PRESSURE GAUGE 12. CONTROL BOX 15 13. V-BELT 14. CHECK VALVE 8 15. SAFETY VALVE 16. PRESSURE SWITCH 17. HOUR METER 16 18. ON/OFF BUTTON 3 [ Fig. 3-1 ] Front view 19. LAMP 2 7 9 2 1 10 14 [ Fig.
GENERAL 3-3 System Diagram 3-3-1CSOF-S3PL(H), CSOF-S5PL(H) [ Fig. 3-3 ] System Diagram The CSOF-S series are an oil-free scroll air compressor. In an operation, a main motor is run to initiate the compression at an airend. The external air is filtered through a suction filter before entering into the airend. The compressed air is stored into an air tank via a check valve (non-return valve). The temperature of the compressed air discharged from the airend is at least 392℉.
INSTALLATION 4.0 Installation 4-1 Inspection When you receive the compressor please inspect it closely. Upon delivery, carefully check the compressor for damage during transportation. If goods are received in damaged condition, it is important that you notify the carrier and insist on a notation of loss or damage across the freight bill. [ Fig.4-1 ] Name plate 4-2 Handling 4-2-1 Handling by a forklift When handling by a forklift, make sure that forks completely extend through the width of the unit. (Fig.
INSTALLATION 4-3 Installation 4-3-1 Where to Install Coaire air compressor is designed for the indoor use. The ventilation facility and piping affect the performance and the service life of the compressor. Please follow the instructions in the user’s manual. [ Fig.4-4 ] Installation of the Air Compressor 4-3-2 Ventilation Poor ventilation in the compressor room may raise the temperature of the air discharged.
INSTALLATION [ Table 4-1 ] Ventilation Fan Capacity Model Air Volume [ ft³/min = CFM ] Hood Size [ Inch x Inch ] CSOF-S3PL(H), CSOF-S5PL(H) 1060 11.8” x 23.6” 4-3-3 Selection of Where to Install [table 4-2] Requirements for Where to Install Item Place Description - Do not install the compressor unit on the outside. - Please keep warm during the winter season, if you have to install on the outside. - Keep the space of more than 31.
INSTALLATION 4-4 Requirements for the Piping 1) Use a larger diameter and install the pipe without an excessive bending to reduce the pressure drop. 2) Always place a branch pipe on the top of a main pipe to reduce the discharge of oil or water. 3) For the compressed air pipes, reduce the number of sections bending and connecting, and the number of valves installed to reduce the pressure loss. 4) The increased pressure loss requires a high discharge pressure of the air compressor.
INSTALLATION 7) It is recommended that the thickness of the cable shall allow more than the minimum requirement specified for a power condenser, and the length of the cable shall be within 1.5 m. No wiring is necessary if there is a power condenser with a sufficient capacity in the bus conductor. 8) Leave intact the factory specification of the overcurrent protection device. If the change is unavoidable, keep the set values within the range specified in the user’s manual.
INSTALLATION [ Table 4-4 ] Electrical Specification OCR Main Power Cable Ground TRIP [A] SET [A] AGW GV [㎟] 30 15 10 15 2.5 32.3 30 10 5 15 2.5 14-13.2 93.8 30 20 15.8 15 2.5 6.6 44.8 30 15 7.9 15 2.5 Voltage Output Input Driving Current Starting Current [V] [kW] [kW] [A] [A] AF [A] 8.4 63.8 460 4.2 208-230 MCCB Model (Poles) CSOFS3PL(H) (4P) CSOFS5PL(H) (4P) 208-230 2.2 3.7 460 2.84 4.
OPERATION 5.0 Operation 5-1 Commissioning ( Initial Operation ) 5-1-1 Structure of the Controller [ Fig. 5-1] Control Button 5-1-2 Checklists before the Commissioning 1) Check if the voltage of the main power is within a normal range specified. 2) Cut the main power to connect the power line to the control panel. 3) Check the connection of pipes, a power supply and a grounding. 4) Fully open a stop valve on the discharge pipe of the compressed air.
OPERATION 5-2 Routine Operation 5-2-1 Checklists before the Operation Check the following conditions before starting the operation. 1) Connect the main power 2) Push the “On/Off” switch into “On” and check the compressor is well started up, and the indicator lamp are normally on.
OPERATION 5-2-4 Stop 1) Push the “On/Off” switch into “Off”. 2) Turn the main power off. 3) Check if the internal pressure is completely discharged from the compressor. 5-2-5 Operation Log Regularly record the information about the operation events in the operation log to early find the failure of the compressor and to prevent the accident before happens. The information includes the discharge pressure, operating time, maintenance items and the time to replace the parts.
FUNCTIONAL DESCRIPTIONS 6.0 Functional Descriptions 6-1 Airend An oil free scroll airend is the most important part in the compressor. In any case, the oil is not entered into the compression chamber. As the inside of the compression chamber is delicate, entering the dusts or foreign substances results in a serious damage to the compressor. The airend consists of precision parts, and needs a special jig for a repair and maintenance.
FUNCTIONAL DESCRIPTIONS 6-3 Cooler & Fan The cooler assembly consists of an air cooler, a cooling fan, a fan motor and a fan shroud (duct). A cooler element is an aluminum cooler that is designed to be used up to 217.5 psi. Dust may increase the temperature in the cooler pin, which needs to be cleaned with the compressed air or a detergent on a regular basis. When cleaning, cover the electric parts to keep the water out. [ Fig.6-3 ] Fan [ Fig.
CONTROL 7.0 Control 7-1 Controller 7-1-1 Operating Conditions 1) Power Supply : AC220V ±5% 50/60Hz 2) Transformer : Min. 50[VA] 3) Operating Temperature : 14℉ ~ 140℉ 4) Operating Moisture : 95% @104℉이하 5) Storage Temperature : -22℉ ~ 176℉ 7-2 Major Functions 7-2-1 Control Panel [ Fig.
MAINTENANCE 8.
MAINTENANCE 8-3 Maintenance 8-3-1 Regular Maintenance of the Airend 1) Check if there is any abnormal vibration or noise during a routine operation, and contact the nearest distributor, if necessary. 2) There are two types of the scroll airend: Low Pressure (115 psi) and High Pressure (140 psi). The maintenance period is different by type specified in the identification plate attached on an airend. The standard specification of Coaire airend is a low pressure type.
MAINTENANCE 8-3-3 Adjustment of the Belt Tension Adjust the belt tension in first 500 hrs after the purchase, and every 3,000 hrs (6 months) thereafter in the following procedures. 1) Use a tensiometer to measure the displacement of each belt. 2) Loose the anchor bolt on the motor base, and use the tension adjusting bolt to adjust the tension with reference to the [Table 8-1]. 3) Align the motor, and tighten the anchor bolt on the motor base.
MAINTENANCE 8-3-5 Cleaning the Suction Filter 1) Check the contamination level every 500 hrs. 2) Replace the heavily contaminated filter even before the replacement period. 3) Blow the element with the compressed air outward, and then by the side. 4) Keep dust and foreign substances out of the compressor during the assembly. [ Fig.8-6 ] Suction filter cleaning Caution A suction filter significantly affects the service life of an airend. Make sure to use only the genuine Coaire suction filter.
TROUBLESHOOTING 9.0 Troubleshooting 9-1 Overview The following flow diagrams show the procedures to repair the typical failures. If the alarm is on and the compressor is stopped, do not restart the operation until the cause is clearly addressed and eliminated. Always turn the main power off, and remove the pressure from the compressor prior to a repair and maintenance.
TROUBLESHOOTING 9-2-3 Unable to Start Motor Unable to start motor - Take necessary action to “Over Yes Check the Lamp - Take necessary action to “High Temp.
TROUBLESHOOTING 9-2-4 No Compression Low discharge pressure Excessive amount of air used Yes - Check the pipe for leakage - Install an additional compressor if the capacity is insufficient No Suction filter is clogged Yes - Clean the suction filter, and replace, if necessary No Airend is damaged Yes - Check the rotation - Check if there is any abnormal noise No Yes Failure of controller - Check the function of a multi-unit control - Check the magnet and the output of the controller No Request a
TROUBLESHOOTING 9-3 Other Troubleshooting Trouble Cause Action 1. Tripped due to 1) Compressor is tripped. 1) Contact the distributor. the overcurrent - Foreign substance in the compressor in motor - Damage to the wrap of the compressor - Low voltage 2. Noise and Vibration - Improve the power supply. 2) Open-phase/Unbalanced power supply 2) Improve the power supply. 3) Deteriorated coil in the motor 3) Check the motor. 4) Failure of OCR 4) Readjust or replace. 1) Fixing bolts are loose.
30mm [1.2"] 620mm [24.4"] 600mm [23.6"] MAIN POWER AIR OUTLET FAN 550mm [21.7"] AIR OUTLET PS 15A(PS1/2") AIR INLET 181mm [7.1"] AIR OUTLET SIROCCO FAN OUTLINE DRAWINGS 10.0 Outline drawings 10-1 CSOF-S3PL(H),CSOF-S5PL(H) 112.5mm [4.4"] 775mm [30.5"] 110mm [4.
2. WIRING COLOR - B: BLACK, BL: BLUE, R: RED, BR: BROWN, W: WHITE, G/Y:GREEN/ YELLOW 1. PRIMARY : 230V,460V, SECONDARY : 110V (100VA) * NOTE * 결선시 결선시 ELECTRICAL WIRING DRAWINGS 11.
STARTUP REPORT Please fill out completely and return to the factory to validate warranty. CUSTOMER AND MACHINE INFORMATION CUSTOMER ADDRESS CITY/STATE PHONE WRITTTEN BY FACTORY SHIP DATE DATE STARTED UP MODEL NUMBER SERIAL NUMBER HOURS ON MACHINE / / / / Hrs. MACHINE INFORMATIONS AND INITIAL STARTUP Compressor Environment- excellent Machine Location – indoors , good , fair , poor . outdoors if outdoors, protected from rain? Yes No . Approx.
Warranty Claim Report Please complete the following claim form, your claim will be confirmed by our sales representative. To : Coaire, Division of Quietside 8750 Pioneer Blvd., Santa Fe Springs, CA 90670 Tel(562)576-1330.Fax(562)699-4351 email: support@coaire.com Date Model Serial No. Run Hours Setting Press. Company Distributor Address Company Customer Address Hrs. PSIG OPERATING CONDITIONS Percent(%) on load No.
QUALITY AND RELIABILITY WITHOUT COMPROMISE COAIRE reserves the right to make changes, at any time without notice as a result of our commitment to continuous improvement.