Specifications

8
1
2
OUTLET
INLET
I H I
3
A
C
E
F
B D
B
A
G
J
Sor ti e
Ent rée
4.1 TECHNICAL SPECIFICATIONS CNC18-CNC75 (115/1/60)
DRYER MODEL CNCM10 CNCM18
Air flow rate at nominal condition
1
[scfm]
[Nl/min]
[Nm
3
/h]
10
285
17
15
425
26
Pressure DewPoint at nominal condition
1
[°F - °C]
38 – 3.3
Nominal ambient temperature
[°F - °C] 100 - 37.8
Max. ambient temperature
[°F - °C] 115 – 45
Min. ambient temperature
[°F - °C] 34 – 1
Nominal inlet air temperature
[°F - °C] 100 - 37.8
Max. inlet air temperature
[°F - °C] 115 – 45
Nominal inlet air pressure
[psig – barg] 100 - 6.9
Max. inlet air pressure
[psig - barg] 232 – 16
Max. outlet air pressure drop - p [psi – bar]
4.4 - 0.3
Inlet-outlet air connection Copper pipe OD 3/8 in. (9.52 mm)
Refrigerant type R134.a (HFC) - CH
2
F-CF
3
Refrigerant charging [oz – g] 6.1/8 - 175 12.3/8 - 350
Cooling air capacity [cfm - m
3
/h]
120 - 200 200 - 340
Power supply [Phase/V/Hz] 115/1/60
Nominal electric consumption [A] 2.2 3.0
Max. electric consumption [A] 2.9 4.2
Compressor power [HP] 1/8 1/5
Weight [lbs - kg] 62 - 28 68 - 31
Max. noise level < 70 dbA at 40in (1m)
1
The nominal condition refers to an ambient temperature of 100°F with inlet air at 100 psig and 100°F
Inches mm
A 14.562 370
B 17.625 449
C 17.437 443
D 2.500 65
E 1.375 35
F 2.00 51
G 2.750 69
H 15.562 395
I 1.062 27
J 2.437 62
K .375 10
L 1.00 26
M .562 14
1-Rocker On/Off Switch-Illuminated
2-Power Supply Cord
3-Condensate Drain