PERSONAL CO2 SAFETY MONITOR AND DATA LOGGER User Manual SAN-10 User Manual R2.0 CO2Meter, Inc. 06321 © Copyright 2021, CO2Meter, Inc. All Rights Reserved.
CONTENTS INTRODUCTION ................................................................................................................................. 2 FEATURES ......................................................................................................................................... 2 MONITOR ........................................................................................................................................... 3 LCD DISPLAY ...............................................
INTRODUCTION Congratulations on your purchase of the SAN-10 Personal CO2 Monitor and Data Logger. It is designed to alert employees who work in enclosed areas where carbon dioxide buildup may cause personal harm. If CO2 buildup occurs, it will show the level on screen, flash, alarm and vibrate. In addition the SAN-10 includes built-in data logging and a man-down alarm that uses an accelerometer to set off the alarm if a sudden shock to the unit (like the wearer falling down) occurs.
MONITOR 1. Visual alarm/strobe 2. Front facing sensor 3. Charging indicator 4. LCD display 5. Power button 6. Menu button 7. USB port and charging inlet (bottom side) 8. Heavy duty metal clip 9. Factory reset button LCD DISPLAY 1. Low alarm indicator 2. High alarm indicator 3. Battery indicator 4. CO2 concentration 5. CO2 concentration units (ppm or % when >9,999 ppm) 6. Calibration icon 7. Man down alarm 8. Data logging indicator 3 © Copyright 2021, CO2Meter, Inc. All Rights Reserved.
OPERATION 2.0 Power button 1.! When the Monitor is turned off, press the power button to turn on the unit. 2.! When the Monitor is turned on, press the power button for 3 seconds to turn off the unit. When the unit is first turned on, it performs 5 seconds countdown for Monitor warm up, then enters normal display with current CO2 readings displayed. The monitor starts taking measurements when power on and updates readings every 2 seconds. 2.
SC (“ Real time clock setup Press the power button ”) to enter the real time clock setup: a. Press the button to switch between Year ( ), Month ( ), Day ( ), Hour ( ), Minute ( ), Second ( ) and . to exit. b. Press the power button to increase the value until the correct time is set. This value is a cyclic change. Press the power button again to save and exit the menu status.
Automatic Atmospheric Pressure Compensation The CO2 measurement is affected by atmospheric pressure or altitude changing. When users are at high altitude, compensation is made internally to ensure maximum monitor accuracy. This device has automatic atmospheric pressure compensation for CO2 concentrations by means of a digital atmospheric pressure sensor integrated in the unit. Man Down Alarm Falling by breathing dangerous gases can cause serious injury and even fatality to workers.
DOWNLOADING DATA LOGS 1. 2. 3. 4. 5. Download latest version of GasLab®: https://www.co2meter.com/pages/downloads Power on the SAN-10 device Wait for 5 second warm up countdown Connect the SAN-10 to your Windows PC with the USB cable Open the Gaslab software 6. Set Sensor Select options. 7. Select the Port in which your SAN-10 device is connected. 8. Do not select a Product. 9. Select SAN-XY under Series/Model. 7 © Copyright 2021, CO2Meter, Inc. All Rights Reserved.
10. Press Connect. When connected the window should appear as shown below: 11. Click Configure Sensor and the following page will appear: 12. Make sure the Serial Number matches the one found on the back of your device. 8 © Copyright 2021, CO2Meter, Inc. All Rights Reserved.
13. Select the Datalogs tab. 14. Click the Download Datalog button. Name and select a location to save your file. Data logs are .CSV (common separated values) files which can be opened or imported into any spreadsheet program. 9 © Copyright 2021, CO2Meter, Inc. All Rights Reserved.
CALIBRATION Step 1. Power the unit on by pressing and holding the power button for 3 seconds Step 2. Press and hold the ºF/ºC button for 5-10 seconds to open the first menu Step 3. Use the ºF/ºC button to scroll through the first menu which will read: a) b) c) d) e) f) AIR N2 L 0.5 H 3.0 A ON E (Ambient Air Calibration Option) (Zero Nitrogen Calibration Option) (Low alarm threshold) (High alarm threshold) (Alarm option. Turns the alarm on and off) (To exit the menu and return to home screen) Step 4.
MAINTENANCE Calibration The SAN-10 comes pre-calibrated from the factory. However, the CO2 sensor should be calibrated at least once a year, or as described in your company’s safety procedures. You can perform the calibration yourself, or you can return it for factory calibration at a nominal fee. Cleaning and Storage Apply sparingly with a soft cloth and allow drying completely before using. Do not use soap or Alcohol cleaning. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
SPECIFICATIONS Dual Beam NDIR (Non-dispersive-Infrared) CO2 diffusion sensor with Automatic Background Calibration (ABC) turned off. Device Specifications Operating Environment Storage Power Supply Dimensions Weight 32°F~122°F (0°C~50°C), <95% RH non-condensing 14°F~140°F (-10°C~60°C), <99% RH non-condensing Li-ion battery (4.2V,1500mAh),Micro USB cable w. Wall USB charger 3.9x2.0x1.7 Inch (98x50x42mm) 4.76 oz. (135 grams) Out of range of operating conditions will impact the accuracy of CO2 measurement.
TROUBLESHOOTING Symptom / Issue Possible Cause / Resolution Cannot power on Press the Power Button for more than 5 seconds Press the reset button as noted on page 6 Check that the Li-ion battery is charged If monitor is charged but will not turn on, contact support Monitor is not recognized by computer or software Verify that software and drivers are installed correctly before attaching monitor to PC.
SUPPORT & WARRANTY The quickest way to obtain technical support is via email. Please include a clear, concise definition of the problem and any relevant troubleshooting information or steps taken so far, so we can duplicate the problem and quickly respond to your inquiry. For more information visit our website: https://www.co2meter.com/ We are here to help! For information or technical support, please contact us. Support@CO2Meter.com (386) 310 - 4933 CO2Meter, Inc.