f. Close the CO DETECT circuit breaker and measure aircraft voltage between
pins 1 and 2 of the CO Detector connector. Pull the CO DETECT circuit
breaker and connect the CO Detector connector to the aircraft harness. Close
CO DETECT circuit breaker.
g. Operational check the unit by verifying the unit comes on with steady green
status LED and with an audible beep from the buzzer. Verify remote alert light
operation.
h. Reset the unit on the panel and verify the CO Detector comes on with steady
green and with an audible beep from the buzzer.
i. Verify the unit can be shut off with the circuit breaker.
j. Unit weights 3.5 oz. Record in Aircraft weight and balance manual.