Specifications

CO Guardian LLC Document No. 01-2510-02
1951 E. AIRPORT DRIVE Date: 11/23/02
TUCSON, AZ. 85706 REV A
Installation:
Install the CO Detector on the instrument panel in view and within reach of the pilot.
Insure that the air intake on the front of the CO Detector is not obstructed.
Install the CO Detector in a location on the instrument panel without high or
disturbed airflow movement. The CO Detector will detect the presence of CO more
effectively if the unit does not have air blowing over it.
Insure that the CO Detector installation area meets the temperature and humidity
ranges listed in the List of Particulars specifications. Temperature and humidity
conditions outside the specification may affect the sensitivity of the alarm.
MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Page 10 of 17