Specifications
64
Issue 01 XYZ Machine Tools July 08
XYZ 560 Mini Mill and 710 VMC Operation Manual
Figure 41 Adjusting the square along the X, Y, Z axis
5.5 Electrical Requirement
For the machine to perform reliably and safely throughout its working life it is essential the
following information is followed by a qualified electrician with machine tool experience.
5.5.1 Power Supply
Ensure all wiring including the ground between the consumer unit and the machine comply with
local wiring regulations.
WARNING - This work should only be carried out by a qualified electrician.
Take care to install an adequate circuit breaker (see table below) at the consumer unit and the
wall isolator.
Thread the power supply cable through the cable inlet positioned at the lower right side of the
machine, rest the cable upon the electric cabinet frame, then connect the cable to the mains
isolator switch and ground of this machine.
These machines are phase sensitive. After checking the tool carousel and cooling fans and if
their direction is wrong, electrically isolate the machine and change over two incoming phases
at the machine isolator.
Rest the cable on the electrical cabinet frame.
Total power capacity of the equipment: 18 kW
No. Voltage
Rated Capacity
Wire
Current-fault breaker
560 710 560 710
1 220 V 65 A 75 A ≥ 22 mm² 70 A 80 A
2 380 V 38 A 44 A ≥ 10 mm² 40 A 50 A
3 415 V 35 A 40 A ≥ 10 mm² 40 A 50 A
xyz-051
SQUARE
RULE
DIAL GAUGE