Specifications

48
Issue 01 XYZ Machine Tools July 08
XYZ 560 Mini Mill and 710 VMC Operation Manual
PCU 50
- Removable hard disk with transportation lock (1 Gbyte for user data)
- MS Windows NT 4.0 operating system (US)
- COM 1 (V.24/TTY), COM 2 (V.24)
- LPT1 parallel interface
- PS/2 mouse, PS/2 keyboard
- Multi-point interface (MPI)
- USB, 2 channels (1 x internal/1 x external)
- Ethernet 10/100 Mbit/s (optional)
- Cardbus (max. Type III)
- Disk drive interface
- Expansion slots: 1 x PCI/ISA + 1 x PCI
PCU 70
- Expansion slots: 1 x PCI/ISA + 3 x PCI (otherwise PCU 70 is identical to PCU 50)
3.4.10 Displays
Screen texts in several languages, switchover function between any two (English,
German, Spanish, French, Italian). Other languages available on request
Program window for block display
Actual position value in 2 to 5 fold character size
Screen saver
Plain text display of operational states
3.4.11 Operation
Transparent operation: operating areas with both horizontal and vertical softkeys
Operator panel disable
User-oriented, hierarchical access protection
OEM-definable user interface configurable under Windows
Complete user interface (user-specific)
3.4.12 Communication
Universal RS232C (V.24)/TTY interface, configuration via plaintext screen
Reading in/out via universal interface parallel to operation
Comprehensive archiving
Data communication with PCIN
Calculation of tool requirements via SINTDI
Communication to host via SINCOM
Data exchange between production planning and production via WINBDE