Instructions / Assembly

Pressure Relief Valve (PRV)
Installation instructions:
The PRV must be connected by the threaded connection
opposite the wing handle on the hot water valve (designated
by the RED Drain handle) or the threaded connection on the
side of the relocation fitting above the hot water valve.
Installation must maintain a ¾ port size with no shut off
valve or line restriction in-between the appliance and the
PRV. The discharge line from the PRV should pitch downward
and terminate 6 above drains where discharge will be
clearly visible. The discharge end of the line shall be plain
(unthreaded) and a minimum of ¾” in diameter. The
discharge line material must be suitable for water at least
180°Fahrenheit and can be no more than 30 feet in length
and contain no more than 4 elbows or bends. No valve of any
type may be installed in the discharge line of the pressure
relief valve.