Tankless Water Heater Kit Installation Guide Model:3006 WARNING: Drain Valves should remain closed during normal operation.
Installation Instructions Inspection and Set-up Check Valve set complete with the following: - Cold Water Valve - Hot Water Valve - Pressure Relief Valve 1.Use and Installation Manual a) Remove tank-less from packaging and inspect contents b) Carefully position tank-less unit front face-up on floor or blocks in a stable location for valve installation 2.
carefully using a back-up wrench to protect the outlet on the tank-less unit e) On the final turn of your wrench position the handle at a slight angle past center of facing forward from the unit f) Next remove the cold water valve from the packaging and hand thread a pipe nipple into the valve inlet g) Use the pipe nipple as handle and rotate the valve handle a couple times to exercise it before installing h) Gently thread cold water valve onto cold inlet of tank-less heater, position of valve should face h
Pressure Relief Valve (PRV) Installation instructions: • The PRV must be connected by the threaded connection opposite the wing handle on the hot water valve (designated by the RED Drain handle) or the threaded connection on the side of the relocation fitting above the hot water valve. • Installation must maintain a ¾ port size with no shut off valve or line restriction in-between the appliance and the PRV.