User`s manual
28
tone generator and the MIDI out port; when Local is set to Off, the keyboard will
only send MIDI data to the MIDI out port.
Operation:
Ö G#2【Local On/Off】
Default: On
Range:
{on}, {off}
7.9 Data Dump
You can dump the keyboard settings by sysx data to other MIDI device, so you
can save and restore the keyboard settings.
Operation: ÖA2【Dump】Ö
MIDI data: F0 00 20 63………F7
7.10 Device Number
When you have several devices with the same model type conneted in your
MIDI system, you can use the Device Number so only the device with the same
device number will receive the corresponded sysx. Besides, the device number
of the keyboard will also be included in all sysxes sent out.
Operation:
Ö A#2【Device Number】Ö【Adjust parameter】Ö
Default: 0
Range: 0-16
7.11 Select Information To DISPLAY
The LED can display many informations, and you can select the needed
information to to be shown on the display. When you click or move a part of the
keyboard like knobs or pads, the part-related informations will be displayed.
7.11.1 Program Number
You can display the current program number (patch or voice number)
Operation:
Ö B2【Program】Ö
Range: 1-128