Specifications
AT command set for XX Siemens mobile phones and modems
__________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September.2004
91
AT+FVRFC=? This command determines the DCE response to a mismatch between the
vertical resolution negotiated for the facsimile session and the Phase C data
desired by the DTE.
An ERROR response code results if this command is issued while the modem
is on-hook
Response:
(List of supported mismatch checking modes)
OK/ERROR/+CME ERROR
Parameter:
<vrfc>
0
disable mismatch checking
2
enable mismatch checking, with resolution conversion of 1-D
data in the DCE and an implied AT+FK command executed
on 2-D mismatch detection
Read command Response:
AT+FVRFC?
<vrfc>
OK
Parameter:
<vrfc>
See Test command
Write command Response:
AT+FVRFC=<vrfc>
OK
Parameter:
<vrfc>
See Test command
2.7 Bluetooth related commands
This section provides descriptions of commands related to Bluetooth applications. AT commands defined in this
chapter are only to be used over a bluetooth connection between mobile and devices such as Headset or Carkit.
These commands are currently specified in the Bluetooth Profile Description and not part of an ETSI
specification [18].
AT+BINP
This command is part of the Handsfree (e.g. Carkit) Profile.
AT+BINP Phone number corresponding to the last voice tag recorded in the HF
Test command Response:
AT+BINP=?
OK/ERROR/+CME ERROR
Write command Response:
AT+BINP=1
+BINP: <number
>, <type>
OK/ERROR/+CME ERROR
Parameter:
<number
>
Telephone number
<type
>
Type of number
AT+BLDN
This command is part of the Handsfree (e.g. Carkit) Profile.
AT+BLDN Redial Last Number
Execute command
Dial Last number!
Similar to ATDL command but only for connection over Bluetooth
AT+BLDN;
Response:
OK/ERROR/+CME ERROR