Specifications

AT command set for XX Siemens mobile phones and modems
__________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September.2004
81
AT+FCQ=<cq>
<cq>
See Test command
AT+FCLASS
AT+FCLASS Select, read or test FAX service class
Test command Response:
AT+FCLASS=?
+FCLASS: (list of supported <n>s)
OK/ERROR/+CME ERROR
Parameter:
<n>
0 data (e.g. EIA/TIA-602 or ITU V.250)
1 Fax class 1 (EIA/TIA-578-A, Service Class 1)
2 Vendor-specific (Fax class 2 (EIA/TIA SP-2388, an early draft
version of EIA/TIA-592-A – asynchronous Facsimile DCE
Control Standard - Service class 2 )
Read command Response:
AT+FCLASS?
<n> OK
Parameter:
<n>
See Test command
Write command Parameter:
AT+FCLASS=<n>
<n>
See Test command
AT+FCR
AT+FCR
Capability to receive
Write command Response:
AT+FCR=<cr>
OK/ERROR/+CME ERROR
Parameter:
<cr> 0
ME cannot receive message data. This value can be used
when the application has insufficient storage. The ME can
send and can be polled for a file.
1
ME can receive message data.
Used for FAX class 2 only
AT+FDCC
AT+FDCC Select service for MO SMS messages
Used for Faxclass 2 only
This command allows the connected application to sense and constrain the capabilities of the
facsimile DCE (=ME), from the choices defined in ITU T.30 Table 2.
Test command Response:
AT+FDCC=?
+FDCC: (list of <vr>s), (list of <br>s), (list of <wd>s), (list of <ln>s), (list of
<df>s), (list of <ec>s), (list of <bf>s), (list of <st>s)
Parameter:
vr
Vertical Resolution
br
Bit rate
wd
Page Width
ln
Page length
df
Data compression Format
ec
Error Correction mode
bf
Binary File transfer mode