Specifications

AT command set for XX Siemens mobile phones and modems
__________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September.2004
79
Used for FAX class 2 only
This command defines the “Copy Quality OK” threshold.
If pixel count errors were detected in normal resolution (98 dpi) mode in as many consecutive lines
as defined in <badlin>, the copy quality is unacceptable.
If pixel count errors were detected in fine resolution (196 dpi) mode in twice as many consecutive
lines as defined in <badlin>, the copy quality is unacceptable.
“Copy Quality Not OK” occurs if either the error percentage is too high or if too many consecutive
lines contain errors
Read command Response:
AT+FBADLIN?
<badlin> OK
Parameter:
<badlin>
See Write command
Write command
AT+FBADLIN=<badlin>
Parameter:
<badlin> 0...255
0 indicates that error checking is not present
or disabled
(Default value: 10)
AT+FBADMUL
AT+FBADMUL
Define, read or test number of bad lines
Used for FAX class 2 only
This command defines theCopy-Quality-OK” multiplier. The number of lines received with a bad
pixel count is multiplied by this number. If the result exceeds the total number of lines on the page
the error rate is considered too high. A threshold multiplier value of 20 corresponds to a 5% error
rate.
Read command Response:
AT+FBADMUL?
OK/ERROR/+CME ERROR
Parameter:
<n> OK
Write command
AT+FBADMUL =<n>
Parameter:
<n> 0...255
0 indicates that error checking is not present
or disabled
(Default value: 20)
AT+FBOR
AT+FBOR
Query the bit order for receive mode
Used for FAX class 2 only
Query the bit order for receive-mode. The mode is set by the ME dependent on the selected Service
Class.
Test command Response:
AT+FBOR=?
+FBOR: (list of supported bit order modes <bor>s) OK
Parameter:
<bor>
0 direct bit order for both Phase C and Phase B/D data
1 Reversed bit order for Phase C data, direct bit order for
Phase B/D data
Read command Response: