Specifications
AT command set for XX Siemens mobile phones and modems
_________________________________________________________________________________________
_________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September, 2004
42
AT+CPBR
AT+CPBR Read a telephone-book entry
Test command Response:
AT+CPBR=?
+CPBR: (list of supported <index
>s), <nlength>, <tlength>
OK/ERROR/+CME ERROR
Parameter:
<index
>
Location number
<nlength
>
Max. length of telephone number
<tlength
>
Max. length of text corresponding to the number
Write command
AT+CPBR=<index1>[,<index2>]
Response:
[+CPBR: <index1>, <number>, <type>, <text >[[…]<CR><LF>
+CPBR: <index
2>, <number>, <type>, <text>]]
OK/ERROR/+CME ERROR
Parameter:
<index1
>
Location number where the read of the entry starts
<index2
>
Location number where the read of the entry ends
<number
>
Telephone number
<type
>
Type of number
<text
>
Text corresponding to the telephone number
<text
> depends on AT+CSCS.
Note:
In the <text
> field, special characters like the following may
be displayed:
`"` (0x22), `@` (0x00), `ò` (0x08), `Ö` (0x5c).
See also section AT+CPBW and
Appendix A: “How to use special characters in certain
commands ( e. g., AT+CPBW”).
Empty entries do not produce any output.
AT+CPBS
AT+CPBS Select a telephone book
Test command Response:
AT+CPBS=? +CPBS: (list of supported <sto>s)
OK/ERROR/+CME ERROR
Parameter:
<sto
>
FD
SIM fix-dialing phonebook
SM
SIM phonebook
DC
ME Dialled Calls List
ON
SIM (or ME) own numbers (MSISDNs) list
LD
SIM last-dialling phonebook
MC
ME missed (unanswered received) calls list
RC
ME received calls list
For a description of telephone-book features, see section 3.1.2.
Read command Response:
AT+CPBS?
+CPBS: <sto
>,<used>,<total>
OK/ERROR/+CME ERROR
Parameter: