Specifications

AT command set for XX Siemens mobile phones and modems
__________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September.2004
41
<n>
See Test command
Write command Response:
AT+CMUT=<n>
OK/ERROR/+CME ERROR
Parameter:
<n
>
See Test command
Note:
Only applicable during an active/hold call
AT+CPAS
AT+CPAS Query the telephone status
Test command Response:
AT+CPAS=?
+CPAS: (list of supported <pas
>s)
OK/ERROR/+CME ERROR
Parameter:
<pas
> 0
Ready
3
Incoming call (phone is ringing)
4
Call is active
Execute command Response:
AT+CPAS
+CPAS: <pas
>
OK/ERROR/+CME ERROR
Parameter:
<pas
>
see Test command