Specifications

AT command set for XX Siemens mobile phones and modems
_________________________________________________________________________________________
_________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September, 2004
40
<ind>,<value>. All indicator events shall be directed from
TA to TE
<bfr> 0
TA buffer of unsolicited result codes defined within this
command is cleared when <mode> 1...3 is entered
1
TA buffer of unsolicited result codes defined within this
command is flushed to the TE when <mode> 1...3 is
entered (OK response shall be given before flushing the
codes)
Read command Response:
AT+CMER?
+CMER: <mode>,<keyp>,0,<ind>,<bfr>
OK/ERROR/+CME ERROR
Parameter:
<mode>
See Test command
<keyp>
See Test command
<ind>
See Test command
<bfr>
See Test command
Write command
AT+CMER=[<mode>],[<keyp>],[<disp>],[<ind>],[<bfr>]
Response:
OK/ERROR/+CME ERROR
Parameter:
<mode
>
See Test command
<keyp
>
See Test command
<disp
>
See Test command
<ind
>
See Test command
<bfr
>
See Test command
Unsolicited result code:
+CIEV: <ind>,<value>
+CKEV: <key>,<press>
Parameter:
<ind>
The number of the indicator according to command AT+CIND=?
<value>
The new value of the indicator according to AT+CIND=?
e.g. +CIEV: 8,101 -> call status indicator (8), new value 'call number
one was released' (101).
<key>
Indicates the key the indication is for (refer values defined in table
for AT+CKPD).
<press>
Status of <key
>
e.g.: +CKEV: "E",0 End key was released
0
<key> released
1
<key> pressed
AT+CMUT
AT+CMUT Mute control
Test command Response:
AT+CMUT=?
+CMUT: (list of supported <n
>s)
OK
Parameter:
<n
> 0
mute off
1
mute on
Read command Response:
AT+CMUT?
+CMUT: <n
>
OK/ERROR/+CME ERROR
Parameter: