Specifications
AT command set for XX Siemens mobile phones and modems
_________________________________________________________________________________________
_________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September, 2004
38
AT+CIND?
+CIND: <ind1>,<stat1>,... <ind10>,<stat10>
OK/ERROR/+CME ERROR
Parameter:
<stat1> battery charge
<stat2> signal quality
<stat3> service
<stat4> message
<stat5> call
<stat6> roam
<stat7> smsfull
<stat8> call status
Remark: the last-issued/buffered call status is displayed
<stat9> GPRS coverage
<stat10> call setup
Remark: The read command does NOT return the current setting of the indicator.
It issues the current value of the indicator, e.g.:
+CIND: 2,3,1,0,0,0,0,0,1,0 which is :
battery charge = 2, signal quality = 3, service = 1, call = 0 ……….etc.
Write command
AT+CIND=[<ind>],[<ind>],[...],….
Response:
OK/ERROR/+CME ERROR
Parameter:
<ind
>
0
the indicator is switched off
1
the indicator is switched on
Remark: Use the AT+CMER=1,x,0,1 command to obtain information of any indicator values as an
unsolicited result code.
AT+CLVL
AT+CLVL Loudspeaker volume level
Test command Response:
AT+CLVL=?
+CLVL: (list of supported <level
>s)
OK
Read command Response:
AT+CLVL?
+CLVL: <level
>
OK/ERROR/+CME ERROR
Write command
AT+CLVL=<level>
Response:
OK/ERROR/+CME ERROR
Parameter:
<level
>
Loudspeaker Volume Level
AT+CMEC
AT+CMEC Mobile Termination control mode
Test command Response:
AT+CMEC=?
+CMEC: (list of supported <keyp
>s),(list of supported <disp>s),(list of
supported <ind
>s)
OK/ERROR/+CME ERROR
Parameter:
<keyp
> 0
MT can be operated only through its keypad (execute
command of AT+CKPD cannot be used)