Specifications

AT command set for XX Siemens mobile phones and modems
_________________________________________________________________________________________
_________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September, 2004
36
OK/ERROR/+CME ERROR
Parameter:
<acmmax
>
see Read command
<passwd
>
String type; usually PIN2
AT+CBC
AT+CBC Battery charge
Test command Response:
AT+CBC=?
+CBC: (list of supported <bcs
>s),(list of supported <bcl>s)
OK/ERROR/+CME ERROR
Parameter:
<bcs
> 0
ME is supplied from battery
1
ME has battery but is not supplied from there
2
ME has no battery connected
3
Error
<bcl
> 0
Battery is flat, no more actions are possible
1-100
charge in per cent
Execute command Response:
AT+CBC
+CBC: <bcs
>,<bcl>
AT+CCLK
AT+CCLK Clock
Test command Response:
AT+CCLK=?
OK/ERROR/+CME ERROR
Read command Response:
AT+CCLK?
+CCLK: <time
>
OK/ERROR/+CME ERROR
Parameter:
<time
>
string type value; format is "yy/MM/dd,hh:mm:ss+zz", where
characters indicate the year (last two digits), month, day, hour,
minutes, seconds and time zone; e.g. “04/05/06,22:10:00+08"
stands for 6th of May 2004, 22:10:00 GMT +2 hours
Write command
AT+CCLK=<time>
Response:
OK/ERROR/+CME ERROR
Parameter:
<time>
see Test command
AT+CIND
AT+CIND Indicator Control
Test command Response
AT+CIND=?
+CIND: ("battchg",(0-5)),
("signal",(0-5)),
("service",(0,1)),
("message",(0,1)),
("call",(0,1)),
("roam",(0,1)),
("smsfull",(0,1))
("call status",(10x-