Specifications
AT command set for XX Siemens mobile phones and modems
__________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September.2004
129
-interrogation of the current <type>,<subtype>,<actNumber>,<maxNumber>
at^sbnw?<CR>
<CR><LF>^SBNW: "vcs",20,2,3<CR><LF>
<CR><LF>OK<CR><LF>
description: The current object which is uploaded is an VCS object.
It has to be stored on record 20.
2 of 3 packets have already been uploaded.
-deleting of record 20
at^sbnw="vcs",20,0<CR>
<CR><LF>OK<CR><LF>
-download entry from record 20
at^sbnr="vcs",20<CR>
<CR><LF>^SBNR: <space>"vcs",20,1,1<CR><LF>
424547494E3A5643414C454E4441520D0A56455253494F4E3A312E300D0A424547494E3A564556454E540
D0A43415445474F524945533A414E4E49564552534152590D0A445453544152543A31393939313231335431
30303030300D0A4445534352495054494F4E3A572E20766F6E205369656D656E730D0A454E443A56455645
4E540D0A454E443A5643414C454E4441520D0A<CR><LF>
<CR><LF>OK<CR><LF>
The mobile divides the record entry into packets of 176 byte (=176*2 characters).
-Download of an empty record 20
at^sbnr="vcs",20<CR>
<CR><LF>OK<CR><LF>
-Test command of AT^SBNW
at^sbnw=?<CR>
<CR><LF>^SBNW: ("bmp",(0)),(„mid“,(0)),(„vcs“,(1-30)) <CR><LF>
<CR><LF>OK<CR><LF>
description: The mobile supports bitmaps of subtype 0, midi obects of
subtype 0 and vcs objects of the subtypes 1 to 30.
4.2 Examples and hints for using GPRS commands
Defining and using a Context Definition Id (CID):
Whenever a CID is used as a parameter for a GPRS command the CID has to be defined first via the
AT+CGDCONT or, for secondary contexts, AT+CGDSCONT command.
To retrieve the parameter of a CID the AT+CGDCONT/AT+CGDSCONT read option must be used.
If the response of AT+CGDCONT/AT+CGDSCONT? is OK only, no CID is defined.
AT+CGDCONT?
OK // no CID defined
All parameters of the CID are initiated by NULL or non-existing values, and the CID itself is set to undefined.
To define a CID use the AT+CGDCONT command with at least one CID parameter.