Specifications

AT command set for XX Siemens mobile phones and modems
_________________________________________________________________________________________
_________________________________________________________________________________________
Document No.: A30880-A10-A001-XX-
D376
Revision: Master R75
Revision Date: 29. September, 2004
112
AT^SPLM
AT^SPLM Read the PLMN list
Test command Response:
AT^SPLM=?
OK/ERROR/+CME ERROR
Execute command: Response:
AT^SPLM
^SPLM: numeric <oper
>,long alphanumeric <oper>[<CR><LF>
^SPLM: numeric <oper
>,long alphanumeric <oper>[…]]
OK/ERROR/+CME ERROR
Parameter
<oper
>
Network operator in numeric and alphanumeric notation
AT^SPLR
AT^SPLR Read an entry from the preferred-operator list
Test command Response
AT^SPLR=?
^SPLR: (list of supported <index
>s)
OK/ERROR/+CME ERROR
Parameter
<index
>
Location numbers
Write command
AT^SPLR=<index1>[, <index2>]
Response:
^SPLR: <index
1>, numeric <oper>
^SPLR: .....
^SPLR: <index
2>, numeric <oper>
OK/ERROR/+CME ERROR
Parameter
<index
1>
Location number where the read of the entry starts
<index
2>
Location number where the read of the entry ends
<oper
>
Network operator in numeric form
AT^SPLW
AT^SPLW Write an entry to the preferred-operator list
Test command Response
AT^SPLW=?
^SPLW: (list of supported <index
>s)
OK/ERROR/+CME ERROR
Parameter:
<index
>
Location number at which the entry is written
Write command
AT^SPLW=<index>[, <oper>]
Response:
OK/ERROR/+CME ERROR
Parameter:
<index
>
See Test command
<oper
>
Network operator in numeric form
AT^SPST
AT^SPST Play Signal Tone
Test command Response: