Specifications

3GPP
3GPP TS 27.007 V6.3.0 (2003-
06)
2
1
Release 6
5.8 ITU-T V.250 [14] generic TA control commands
Table 9: V.250 generic TA control commands
Command
Subclause
Impl.
Use in GSM/UMTS
Z[<value>]
6.1.1
mand.
TA sets all parameters to their defaults as specified by a user
memory profile or by the manufacturer, and resets TA
&F[<value>]
6.1.2
mand.
TA sets all parameters to their defaults as specified by the
manufacturer
I[<value>]
6.1.3
opt.
request manufacturer specific information about the TA (software
cannot use this command to determine the capabilities of a TA)
+GMI
6.1.4
mand.
request TA manufacturer identification (may equal to +CGMI)
+GMM
6.1.5
mand.
request TA model identification (may equal to +CGMM)
+GMR
6.1.6
mand.
request TA revision identification (may equal to +CGMR)
+GSN
6.1.7
opt.
request TA serial number identification (may equal to +CGSN)
+GOI
6.1.8
opt.
request ISO system global object identification of the TA (general
format defined in ITU-T Recommendation X.208; encoding rules
in ITU-T Recommendation X.209)
+GCAP
6.1.9
mand.
request overall capabilities of TA; the response code for a TA
building on this document shall be +CGSM
+GCI=<T.35>
6.1.10
opt.
selects the country of installation for the TA using ITU-T
Recommendation T.35 Annex A country codes
5.9 PCCA STD-101 [17] select wireless network +WS46
PCCA STD-101 [17] includes a command to select the cellular network (Wireless Data Service; WDS) to operate with
the TA. PCCA calls this WDS-Side Stack Selection. This command may be used when TA is asked to indicate the
networks in which it can operate.
Table 10: +WS46 parameter command syntax
Command
Possible response(s)
+WS46=[<n>]
+WS46?
<n>
+WS46=?
(list of supported <n>s)
Description
Set command selects the WDS side stack <n> to be used by the TA. Read command shows current setting and test
command displays side stacks implemented in the TA.
Defined values for Query
<n>:
12 GSM Digital Cellular Systems (GERAN only)
22 UTRAN only
25 3GPP Systems (both GERAN and UTRAN)
NOTE: These 3 values are mutually exclusive. e.g. if value “25” is returned, value “12” and “22” shall not be
returned.
Defined values for Set
<n>:
12 3GPP System