User`s manual
CBI-tOtO
4
Name
the tape drives
and
list drive unit by entering the following line:
disk
raO
at
uq#
drive~
disk
ral
at
uq#
drive~
Where
# = the same number used to represent the controller
in
step
3.
~
= the DU
number
in the On-Board Utility displays this configuration.
CBI-1
01
O/TM
Edit the configuration file
by
performing the following instructions for the
CBI-1010/TM. Note the CBI-I010/TM
must
be configured
with
a higher
klesiu
number,
higher
uq
number,
and
higher
tms
numbers
than
any other
klesiu
controller;
and
a higher
uda
number,
higher
uq
number,
and
higher
ra
number
than
any other
uba
controller
in
the configuration file.
1 Make sure the following two lines are
in
the configuration file:
adapter
xmiO
at
nexus? (this line only for
VAX
6000's
and
5810's)
adapter vaxbi&
at
nexus?
Where
? = the system will fill
in
this variable (simply enter
this?
).
& = the
XMI
node ID of the
XMI
to
BI
adapter for 6000's
and
5810's (on
8200's use
0,
zero, for the variable).
2 Connect the controller to the node
on
the
BI
bus
by
entering the
following line:
controller ubat1
at
vaxbi& node
XX
Where
t1
= the variable number that represents the CBI-1010 /TM.
& = the same
number
used
in
step 1.
XX
= the node ID of the
VAXBI
slot that contains the CBI-1010/TM.
Setup
4-21