User`s manual

CBI-1010
4-10 Setup
3 To reconfigure the device select option C
and
the screen will prompt
you
with
the following question as shown
in
Figure 4-5.
WARNING
Use homogeneous high quality twisted pair cables within
SCSI
specifications
for
5-MB/sec transfer rate.
Enter Synchronous transfer rate (MB/sec)
Enter
(4-10)
Figure 4-5: Synchronous transfer rate change
4 Enter synchronous rate from 4 to
10
MB/sec. The screen will prompt
you
to answer the next series of questions as shown
in
Figure
4-6.
Enter Initiator
ID
7
Number of Disks?
(0-7)
4
DUO
to be Reconfigured ? (YIN) N
DU1
to
be
Reconfigured? (YIN) N
DU2
to
be
Reconfigured? (YIN) N
DU3 to
be
Reconfigured? (YIN) N
Number of Tapes?
(0-3)
3
MUO
to
be
Reconfigured? (YIN) N
MU1
to
be
Reconfigured? (YIN) N
MU2 to
be
Reconfigured? (YIN) N
Figure 4-6:
SCSI
host
adapter
10
change
5 Enter Initiator
SCSI
ID 7 or the required Host Adapter
SCSI
ID (default
is
7). Enter the
number
of disk
and/or
tapes. Default configuration is
four disks,
and
three tapes;
it
is
not
necessary to configure
if
running
fewer than four disks
and
three tapes.
NOTE
If zero is selected for the
number
of disk or tapes, place
a
shunt
over the appropriate pins
on
jumper WI. See
Table
3-2
on
page 3-3.
Answer
Y or N to reconfigure each of the disks or tapes.
If
you answer
Y,
the screen will
prompt
you
with
these questions: