User`s manual
CBI-1010
4-4 Setup
4 The monitor will display QUALIFY STARTED <SEQUENTIAL WRITE
AND
READ>! <HIT <BREAK>
TO
ABORT>.
5 The monitor will display TESTING LOOP
COUNT
AND
BLOCK NUMBER:
6 Press [BREAK] to exit back to the
main
menu
after
you
are satisfied
with
the qualifying process.
Manually Replacing Bad Sectors
This option allows
you
to replace
bad
sectors manually. The controller
supports
dynamic defect management which replaces defective sectors on-line
so there is
no
need
to manually replace
bad
sectors. However,
if
you
wish to
replace
bad
sectors manually follow these instructions; remember that any
data
in
the sector will be lost:
1 Select option 4 from the
main
menu.
2 Enter the device
number
at the statement: DEVICE
NUMBER?
DEV <0 TO 6>:
3 Enter the logical block
number
in
HEX at the statement: ENTER THE BAD
BLOCK NUMBER <HEX>:
4 The monitor will display
-BAD
BLOCK
REPLACED-
when
finished
executing.
Additional Utilities
To access additional utilities for disk drives, select option 5 from the main
menu.
To
access additional utilities for tape drives, select option 7 from the
main
menu. The additional utilities
menu
will display as
shown
in
Figure
4-2.
ADDITIONAL UTILITIES (REV. YVYxZ2.)
SN
= 1278X
D = DISPLAY SCSI DEVICE AND SET UP CONFIGURATION
S
= SEND SCSI COMMAND TO THE DEVICE
T = TEST SCSI DEVICE
R = FORMAT RCT BLOCK
SELECT
OPTION?
Figure
4-2:
Utility
Sub-menu