Owner’s Manual Keep with machine for reference MODEL UC50e INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.
TABLE OF CONTENTS MODEL UC50E 1. SPECIFICATIONS ........................................................................................ 2 1.1. 2. GETTING STARTED..................................................................................... 3 2.1. 3. RECEIVING AND INSTALLATION.............................................................................................. 3 2.1.1. Electrical .........................................................................................................
1. Specifications 1.1. METRIC EQUIVALENT Model UC50e WATER CONSUMPTION PER RACK .8 GAL. (3 L) PER HOUR 24/16 GAL. (90/60 L) WASH TIME-SEC 100/160 100/160 RINSE TIME-SEC 15/15 15/15 5/5 5/5 2/3MIN. 2/3MIN. 30/20 30/20 6.87 GAL. (26 L) 140°F (60°C) OPERATING CYCLE DWELL TOTAL CYCLE OPERATING CAPACITY RACKS PER HOUR WASH TANK CAPACITY WATER REQUIREMENTS WATER INLET DRAIN CONNECTION RINSE PRESSURE SET 3/4” - 1” - 24 PSI 1.
Getting Started 2. Getting Started 2.1. Receiving and Installation The dishwasher is shipped from the factory in a corrugated box on a wooden pallet. The installation guidelines give a systematic procedure for setting up the machine. Start by removing the packaging material. After removing the packing, ensure that the appliance has not been damaged in transport. If it has, inform the retailer. Set the machine in place, and level from side-to-side and front-to-back. 2.1.1.
Getting Started 2.1.4. Detergent dispenser. The machine is equipped with detergent dispenser, which automatically draws the product. Detergent has been pre-wired prior to the shipment. Refer to wiring diagram on the page 8 for detergent dispenser connection. Chemical output line is connected to the injector on the back of the machine. Insert chemical input line with the filter in detergent container. Prime detergent dispenser and proceed to dispense.
Operatation 3. Operation 3.1. Control Panel And Relative Symbols. ON/OFF PUSH BUTTON CYCLE START PUSHBUTTON TIME SELECTOR PUSHBUTTON DRAIN PUMP PUSH BUTTON 3.2. • • Startup Procedures Insert the overflow tube in the special seat inside the wash tank. Check that the suction filter inside the wash tank is correctly fitted in its seat. The filter must be cleaned after every 20 wash cycles and whenever necessary. • DO NOT use the appliance without the filter Close the dishwasher door.
Operatation • To begi n the wash cy cle pre ss Cycle Start push button. The button light will co me on , indicating that the cycle has started. At the end of the washing cycle, a hot rinse cycle will take place. The indicator light of the Cycle Start button will turn off when the cycle has finished. • • The appliance is now ready for a new wash. At the end of the day, clean the machine (see "Preventive Maintenance"). 3.3. Preventive Maintenance. 3.3.1. Regular Maintenance.
Operatation 3.4. PROBLEM The machine does not start The machine does not draw water Troubleshooting.
Electrical Diagram 4. Electrical Diagram MODEL UC50e INSTALLATION & OPERATION MANUAL Rev. 1.