Owner`s manual
Title
Rev 1.02
Installation & Operation
Model EAH / EC Dishwasher
02/07/11
4. Chemical Feeder
The peristaltic pumps are assembled and included within the machine.
5.
Scrap Trap Accumulator
The scrap trap accumulator is designed to perform two basic functions:
It allows a method to discharge all the heavy solids out of the machine with each wash and rinse
cycle.
It provides capacity to drain the contents of one cycle regardless of the ability of the existing drain
to accept the discharge rate.
There is a drain connection sleeve (2”) on the bottom of the scrap accumulator (See drain connection
instruction).
CMA standard dishwashers operate on 110 volts. Other voltage requirements are available on request.
When installing the single rack units, either model EAH or EC, it is recommended that a clean 20 amp
circuit be provided to the machine.
WARNING: Electrical and plumbing connections need to be made by a qualified service person who
will comply with all available Federal, State, and local Health, Electrical, Plumbing Safety Codes.
SCRAP TRAP ACCUMULATOR CONNECTION:
Page 5
N
ot supplied with
Machine