Owner's Manual

MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.08A Page
3
1.1. CMA-180/CMA-180T
Note: The required flowing water pressure to the dishwasher is 15-65 PSIG. If pressures higher
than 65 PSIG are present, a pressure regulating valve must be installed in the water line to the
dishwasher (by others). If flowing pressure is lower than 15 psi, improper machine operation may
result.
ELECTRICAL RATING
VOLTS PHASE AMPS
WITHOUT BOOSTER
(both High and Low Temp)
208 1 36
240 1 38
208 3 24
ELECTRICAL RATING
WITH BOOSTER (High Temp)
240
480
208
240
208
240
480
3
3
1
1
3
3
3
26
10
78
88
49
55
25
SHIPPING WEIGHT
WITHOUT BOOSTER
WITH BOOSTER
332#
375#