Owner`s manual

MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.01B PAGE
3
1.2. GLX Operational Cycle
The GLX Operational Cycle has a total cycle time of 2 minutes (120 seconds). The
Timing Diagram and the steps listed below detail the individual functions that are
executed during each Operational Cycle.
Seconds: 0 10 20 30 40 50 60 70 80 90 100 110 120
F
L
U
S
H
1. With the machine powered up, toggling the START switch begins a cycle.
a) Toggling the START switch energizes both the cam timer motor and the instant
start relay. The instant start relay latches ON the power to the cam timer motor so
that the START switch can be released a moment after it has been toggled without
the cam timer motor losing power.
b) After about 2 seconds, Cam 1the Start camlatches ON the power to the cam
timer motor and drops out the instant start relay. The cam timer motor continues
FILL
Start/Stop
Detergent
Drain
Flush/Fill
Sanitizer
Rinse
Pump Motor
Heater
WASH
RINSE
Instant
Start Relay
Cam 1
Cam 2
Cam 3
Cam 4
Cam 5
Cam 6
Cam 7
Cam 8