Owner`s manual

Maintenance
MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.01B PAGE
12
4.3. Troubleshooting
PROBLEM
LIKELY CAUSE
SOLUTION
Machine inoperative
Power off at circuit breaker
Reset circuit breaker
Defective power switch
Replace power switch
P/N: 15524.00
Defective timer assembly motor
Replace timer assembly motor
P/N: 00501.00
Pump Motor inoperative
Door is open
Close door
Control drawer is pulled out
Secure control drawer
Defective reed (door) switch
Replace reed (door) switch
P/N: 00556.10
Defective timer assembly
(Cam 7)
Replace timer assembly*
P/N: 00408.80
Defective pump motor contactor
Replace contactor
P/N: 00404.82
Defective pump motor
Replace pump motor
P/N: 00201.00
Pump Motor runs with door
open
Defective reed (door) switch
Replace reed (door) switch
P/N: 00556.10
Defective pump motor contactor
Replace contactor
P/N: 00404.82
Delime switch is on
Turn off delime switch
Motor runs continuously
Delime switch is on
Turn off delime switch
Optional Sustainer Heater
(no heat)
Defective thermostat on heater
Replace heater
P/N: 04109.11
Defective heater relay
Replace heater relay
P/N: 00631.00
Defective timer assembly
(Cam 8)
Replace timer assembly *
P/N: 00408.80
Defective heater
Replace heater
P/N: 04109.11
Defective float switch
Replace float switch
P/N: 13463.00
Float switch not actuated
Fill wash tank completely
Level machine
Optional Sustainer Heater
(never turns off)
Defective thermostat on heater
Replace heater
P/N: 04109.11
Defective timer assembly
(Cam 8)
Replace timer assembly *
P/N: 00408.80
Defective heater relay
Replace heater relay
P/N: 00631.00
*The timer assembly motor (P/N: 00501.00) or micro switches (P/N: 00411.00) can be replaced
independently if that is the only component that has failed.