Specifications

MODEL CMA-180 Service & Parts Manual Rev. 2.02A
9
3. Wiring Options
Figure 1-A
3-Phase and 1 Phase
Wiring Options
Single-Source
220V 3-Phase
(20 amp/12 g*)
Single-Source
220V 3-Phase
(50 amp/8 g*)
Single-Source
220V 1-Phase
(80 amp/4 g*)
DUAL-Source
220V 1-Phase
(50 amp/8 g*)
(30 amp/10 g*)
Single-Source
220V 1-Phase
(30 amp/10 g*)
(without Booster) (without booster)
DISPENSER HOOK-UP
1. The power signal is 208/230 volts. The power block is labeled inside the control panel.
Conduit holes for both detergent & rinse are supplied in the control panel.
2. A threaded (1/8ā€) injection point is provided on the final rinse Teflon mixing chamber
located off the back of the machine.
3. A (7/8ā€) hole is provided in the tank for a probe access. It is located on the front side of
the wash tank behind the wash tank heater cover.
MAIN POWER CONNECTION
Please refer to the machine data plate or choose one of the five (5) power connections illustrated
above (Figure 1-A). Electrical requirements are shown for machines with or without booster
heater, three or single phase.
WARNING: Insure that the machine is properly grounded and complies with all local and national
codes. INJURY OR DEATH MAY OCCUR FROM SHOCK, IF THE MACHINE IS NOT
PROPERLY GROUNDED.
Install power supply wires, L1, L2 and L3 (3-Phase) to the appropriate terminals marked L1, L2,
and L3 on the power block. (If applicable, the high or ā€œwildā€ leg must be connected to the L2
Terminal.)
g*=gauge