Specifications

INSTALLATION
Form No. EBOOSTERM-0712
21
Temperature/
Pressure Gauge
Pressure Reducing Valve
with High Pressure By-pass
(20 psi [138 kPa] flow
pressure maximum)
Temperature/
Pressure Gauge
Shock Absorber
for water hammer
Outlet to
Dishwasher
Discharge from T/P Valve.
Air gap must comply
with plumbing code.
3/4” Gate or
Ball Valve
Water Inlet from
primary water
heater
Blended Phosphate Water
Treatment System
Back
Pressure
Relief Valve
Inlet
Temperature/Pressure
Relief Valve, 150 PSI/210°F
(1040 kPa/99°C)
Flow
Restrictor
Floor Drain
Drain Valve
NOTE: Centerline of booster “T” fitting must
not extend closer than 102 mm (4″) to the floor.
Temperature/
Pressure Gauge
Temperature/
Pressure Gauge
Floor Drain
Shock Absorber
for water hammer
Outlet to
Dishwasher
Discharge from T/P Valve.
Air gap must comply
with plumbing code.
3/4” Gate or
Ball Valve
Water Inlet from
primary water
heater
Blended Phosphate Water
Treatment System
Outlet
Back
Pressure
Relief Valve
Inlet
Drain Valve
Pressure Reducing Valve
with High Pressure By-pass
(20 psi [138 kPa] flow
pressure maximum)
Temperature/Pressure
Relief Valve, 150 PSI/210°F
(1040 kPa/99°C)
Mini-Compact Models
Compact Series
Not supplied, but is available as an option/accessory.
Not supplied with booster heater.
Plumbing Connections
Valves, gauges, and unions must be installed per diagram
to ensure proper operation, servicing, and warranty
coverage.
WARNING