Specifications

INSTALLATION
Form No. EBOOSTERM-0712
20
Temperature/
Pressure Gauge
Temperature/
Pressure Gauge
Shock Absorber
for water hammer
Outlet to
Dishwasher
Discharge from T/P Valve.
Air gap must comply
with plumbing code.
3/4” Gate or
Ball Valve
Water Inlet from
primary water heater
Blended Phosphate Water
Treatment System
Outlet
Drain Valve
3/4”
Union
Back
Pressure
Relief Valve
Inlet
Floor Drain
Outlet
Inlet
NOTE: Centerline of booster “T” fitting must
not extend closer than 102 mm (4″) to the floor.
Pressure Reducing Valve
with High Pressure By-pass
(20 psi [138 kPa] flow
pressure maximum)
Temperature/Pressure
Relief Valve, 150 PSI/210°F
(1040 kPa/99°C)
Temperature/
Pressure Gauge
Temperature/
Pressure Gauge
Floor
Drain
Shock Absorber
for water hammer
Outlet to
Dishwasher
Discharge from T/P Valve.
Air gap must comply
with plumbing code.
3/4” Gate or
Ball Valve
Water Inlet from
primary water
heater
Blended Phosphate Water
Treatment System
Outlet
3/4”
Union
Back
Pressure
Relief Valve
Inlet
Drain
Valve
Pressure Reducing Valve
with High Pressure By-pass
(20 psi [138 kPa] flow
pressure maximum)
Temperature/Pressure
Relief Valve, 150 PSI/210°F
(1040 kPa/99°C)
NOTE: Centerline of booster “T” fitting must
not extend closer than 102 mm (4″) to the floor.
Two Imperial Models Connected in Series
Imperial “S” Series
Not supplied, but is available as an option/accessory.
Not supplied with booster heater.
Plumbing Connections
Valves, gauges, and unions must be installed per diagram
to ensure proper operation, servicing, and warranty
coverage.