User Manual
P/N: 192047082 (REV AA) 627NH January 2018
32
LL1 (flashing)
Lower Limit 1
Err
Lower Limit 1-SLOW Down Indicator. Hoist has reached lower slow approach
limit. No action is required. If desired, slow approach limits may be disabled as
described on page 18.
1. May not require corrective action.
2. Check the position of the Limit Switch.
LL2 (flashing)
Lower Limit 2
Err
Lower Limit 2-STOP Indicator. Hoist has reached lower limit. Run hoist UP
away from lower limit, or if limit is in an inappropriate place, reset limits as
described on page 18.
1. May not require corrective action.
2. Check the position of the Limit Switch.
MNT
Maintenance
Required
Maintenance Required Alert. Running time has exceeded C12.05
1. Reset timer by MFI=5A or depress Mode/Service
key three times and enter within 2 seconds.
OC
Over Current
Output current exceeds 200% of inverter rated output current.
1. Check for a phase-to-phase short in the motor or
wiring using a megger.
2. Extend the acceleration/deceleration time.
3. Check torque limit setting.
OH (flashing)
Heatsnk Over
temp
Overheat Pre-Alarm. Heatsink is overheating. The temperature of the inverters
heatsink exceeded the setting in L08.02.
1. The inverter cooling fan has stopped.
2. Reduce the ambient temperature.
OH1
Heatsink
MaxTemp
Overheat Fault. There are two situations that result in an overheat fault. The first
occurs when the measured heat sink exceeded 105°C. The second is a result of a
fault in the internal 24VDC cooling fan.
1. Ensure that the heat sink cooling fans are function-
ing.
2. Ensure that the heat sink is free from dirt and
debris.
3. Ensure that the inverter’s ambient temperature is
within specifications.
4. Replace the 24VDC fan.
5. Replace the heat sink thermistor(s).
OH2
(Flashing)
Overheat 2
Overheat Alarm. Signal is input by external terminal. H01.XX=39
OH3 Motor
Overheat 1
Motor Overheating 1. Thermistor analog input detected motor overheating.
See L01.03.
1. Check the motor rated current value, E02.01.
2. Increase cycle time OH4 Motor or reduce the load.
OH4 Motor
Overheat 2
Motor Overheating 2. Thermistor analog input detected motor overheating.
See L01.04.
OL1
Motor
Overloaded
Motor Overload Fault. Inverter output exceeded the inverter overload level.
1. Ensure drive is programmed with proper motor full
load Amps (E02.01).
2. Reduce the load.
OL2
INV Overload
Inverter Overload Fault. Inverter output exceeded the inverter overload level.
1. Reduce the load.
2. Extend the acceleration time.
OPE01
kVA Selection
kVA Settings Fault. Inverter kVA setting range is incorrect. 1. Check O02.04 constant for proper kVA.
OPE02
Parameter Range Setting Error. Parameter settings are set outside the
parameter range.
1. Press enter to view parameter.
2. Change parameter to appropriate setting.
OPE03
Terminal
Multi-Function Input Settings Fault. Set values other than “F” and “FF”
are duplicated.
1. Check the settings for H01.01 to H01.07, vertify
that the same input is not used twice.
OPE04
Terminal
Parameters do not match. The drive, control board, or terminal board has been
replaced, and the parameter settings between the controller board or terminal
board do not match.
1. Press ENTER to view the parameter.
2. Change parameter(s) to appropriate settings.
3. Set A01.05 = 5550.
OPE07
Analog Selection
Multi-Function Analog Input Setting Fault. Set values other than 00 and 0F
are duplicated.
1. Check setting for H03.02 and H03.10. Verify that
the same value is not used twice.
OPE08
Terminal
Selection Parameter error. A parameter has been changed that is not available
in the present control method.
1. Undo the last parameter change (if known).
2. Scroll through modified constants for obvious
setting error.
3. Perform a user initialize (A01.05=1110)
CAUTION: All settings will be restored to
the factory defaults.
OPE10
V/fPtm Setting
V/f Parameter Setting Error. 1. Check Parameters E01.04 to E01.11.
OPE23
Load Check
Check C05.04≤C05.07≤C05.09. 1. Load Check setting error.
OT1
Overtorque
Det 1
Overtorque Detection Level 1 Fault. Current is higher than set value (L06.02)
for more than set time (L06.03).
1. Check for proper programming of L06.02 and
L06.03.