Owner`s manual
*Master/Slave Message Tx/Rx/Echo/Echoinc Message
Route Mode Control Messages
*Master/Slave Route Mode On Rx BN-60-02
*Master/Slave Select Source Rx, Tx BN-62-Source
* % Master/Slave Destination OFF Rx, Tx BN-63-Destination
* % Master/Slave Destination ON Rx, Tx BN-64-Destination
*Master/Slave Read Source assignments Rx BN-65-Source
*Master/Slave Read Destination Source Rx BN-66-Destination
*Master/Slave Read Source Stereo assignments Rx BN-67-Source
*Master/Slave Source Stereo assignments Rx, Tx BN-68-Source
Note: Source (R) not equal Source (L) + 1 = turn stereo off BN-68-Source (R)
*Master/Slave Read Dest Stereo assignments Rx BN-69-Destination
*Master/Slave Destination Stereo assignments Rx, Tx BN-6A-Destination (L)
Note: Destination (R) not equal Destination (L) + 1 = turn stereo off BN-6A-Destination (R)
Level Mode Control Mesages
*Master/Slave Level Mode On Rx BN-60-03
*Master/Slave Read Source Level Rx BN-6B-Source
*Master/Slave Source Level Rx, Tx BN-Source-Level
Note: Level from 00 to 106 (decimal) is -96dB to +10dB
*Master/Slave Source Right Channel Tx BN-Source-7F
*Master/Slave Destination Level Rx BN-6C-Destination
*Master/Slave Destination Level Rx, Tx BN-Destination + 20-Level
*Master/Slave Destination Balance Tx AN-Destinatio + 40-Balance
*Master/Slave Set Source 1-16 Absolute Rx BN-40-Level (Absolute)
*Master/Slave Set Source 17-32 Absolute Rx BN-41-Level (Absolute)
*Master/Slave Set Source 1-32 Absolute Rx BN-42-Level (Absolute)
*Master/Slave Set Source 1-16 Relative Rx BN-43-Level (Relative)
*Master/Slave Set Source 17-32 Relative Rx BN-44-Level (Relative)
*Master/Slave Set Source 1-32 Relative Rx BN-45-Level (Relative)
(Note: Relative, 3F = no change. Above 3F is positive, below 3F is negative .)
*Master/Slave Set Destin 1-16 Absolute Rx BN-46-Level (Absolute)
*Master/Slave Set Destin 17-32 Absolute Rx BN-47-Level (Absolute)
*Master/Slave Set Destin 1-32 Absolute Rx BN-48-Level (Absolute)
*Master/Slave Set Destin 1-16 Relative Rx BN-49-Level (Relative)
*Master/Slave Set Destin 17-32 Relative Rx BN-4A-Level (Relative)
*Master/Slave Set Destin 1-32 Relative Rx BN-4B-Level (Relative)
(Note: Relative, 3F = no change. Above 3F is positive, below 3F is negative .)
Serial Control Specifications
CM Labs SixtyFour Owner’s Manual Page 15