Specifications
TH82 Series Reference Manual
20/20
DLE DC4 Real-time pulse output
[FORMAT] <10>H<14>H<n><m><t>
[RANGE] n=1
m=0,1
1≦t≦8H
[FUNCTION] This command outputs the pulse specified by t to connector pin m as follows.
The pulse ON time is t x100msec. and the OFF time is t x100msec..
[DETAILES] *This command is ignored when the printer is in an error status while this command is processed.
*When ESC p or DEL DC4 is executed, this command is ignored and no pulse is sent.
*This command is executed when the data is received.
*This command is executed even when the printer is off-line, the receive buffer is full, or an error
occurs.
*This command is effective even when the printer is disabled with ESC = (selected peripheral
device).
[CAUTION] *The user must notify that the printer performs the same operation with this command if
printer receives the same character strings with this command
*This command must not be used within the data sequence of another command that consists of
two or more bytes.
DLE EOT Real-time status transmission
[FORMAT] <10>H<04>H<n>
<1D>H<04>H<n>
[RANGE]
1≦n≦4H
[FUNCTION] Transmits the printer status specified by n in real-time.
n=1 Transmit printer status
n=2 Transmit offline status
n=3 Transmit error status
n=4 Transmit paper roll sensor status
[CAUTION] *The printer transmits the status without confirming if the HOST is ready to receive data.
*The user must notify that the printer performs the same operation with this command if
printer receives the same character strings with this command
*This command must not be used within the data sequence of another command that consists of
two or more bytes.
*When Auto Status Back (ASB), GS a command, is effective, the status transmitted by the DLE
EOT and the ASB status should be differentiated.
n = 1: Printer status
VALUE
BIT Function
0 1
0 Not used Fixed to off -
1 Not used - Fixed to off
m Connector pin
0 Plug 1
1 Plug 2