Installation Guide

VA Series Installation Guide V1.1 9
Front panel – connections and controls
PROTECT
CLIP
SIGNAL
POWER
1
2
3
4
POWER
VA
4 CHANNEL POWER AMPLIFIER
4120
1 2 3 4 55
VA 4120
PROTECT
CLIP
SIGNAL
POWER
1
2
POWER
VA
2 CHANNEL POWER AMPLIFIER
2120
2 1 45 3
VA 2120
1. SIGNALa green LED for each channel which illuminates when the channel’s signal level is above -45 dB relative to the
maximum power output. In most installations, it can be used to conrm that the channel’s source is active.
2. CLIP an amber LED for each channel which illuminates when the channel’s signal level is within 1 dB of nominal peak
power. If this LED ashes more than occasionally, it is likely to indicate that the limiter is active and that the signal level should
be reduced, either at the rear panel LEVEL control for the channel, or at the source itself.
3. PROTECT a red LED for each channel which indicates a fault condition: it illuminates when the channel’s protection
circuitry is active. If this occurs, the output terminals are temporarily disconnected until the fault condition clears. The
protection circuitry will be triggered either by over-temperature within the amplier, or by the detection of DC at the
output terminals.
4. POWER turns the mixer-amplier on and off. When it is on, the green POWER LED is illuminated.
5. Air intakes airow through the mixer-amplier is from front-to-back. The VA2120 has a single front panel vent, the VA4120
has two. Do not allow the vents to become blocked, as over-temperature will cause the protection circuitry to shut the
amplier down.