User guide

DCM-1 User Manual v1.0
Conguration
38
Power Up Mode
selects Power Up optionRotary:


It will often be desirable for the DCM-1’s settings, such as
input selections, levels, etc., to be automatically restored
when it is re-powered after being off for a period
(intentionally or otherwise). The Power Up Mode function
determines the state the DCM-1 “wakes up” in when it is
powered-up.
The rotary control selects the active Power Up option from
the three available: Factory, Defaults and Last Known.
With Factory set, the DCM-1 will always return to its
original factory settings on power-up. This is the default
option. A list of the factory settings can be found at page 55.
If Power Up Mode is set to Defaults, the settings which
have been saved by the user in the Defaults memory (see
below) are restored. The third option, Last Known, will
restore the DCM-1 to the settings they were in when the
unit was last powered off.
The numeric buttons are not used in this function.
Save Defaults
Press: stores current settings

When the rotary control is pressed in, all the unit’s current
settings are stored in the Default memory. The contents of
this memory is then re-loaded on power-up, if Defaults is
set as the option in the Power Up Mode function (see
above).
The numeric buttons are not used in this function.
Update Firmware
3 times to enable firmware updatePress:

This menu function is used when a rmware update is
installed. See page 54 for full details of rmware Updates.
Pressing the control knob three times in quick succession
prepares the DCM‑1 for the rmware update. The X in the
display changes to a
ü
. At this point a further press cancels
the procedure. Otherwise, the DCM-1 will install the new
rmware next time it is reset (see Reset Mixer below), or
re-powered.
Neither rotation of the control knob nor the numeric
buttons are used in this function.
Reset Mixer
Press: resets Mixer

This menu function can be used to perform a hardware
reset. This is equivalent to powering the DCM-1 off and back
on again.
Press the rotary control to perform the reset. The unit
exits Installer Mode and the display returns to the User
Mode default. No other front panel controls are used in this
function.