User guide

Conguration
DCM-1 User Manual v1.0 35
System Menu
CDR Zone Setup
select ZoneButtons:

The CDR ZONE SETUP menu function lets the operator
put the CDR-1s in a system into Engineers Mode. In this
mode, per-Zone output EQ can be adjusted locally, in the
zone itself. This permits much faster and easier optimisation
of the sound as the adjustment is made from the CDR-1(s)
rather than from the DCM-1.
The eight numeric buttons correspond to the eight Zones;
select the Zone(s) where EQ is to be adjusted by pressing
the appropriate key(s). The default is for EQ Setup Mode to
be OFF for all Zones. A second press exits the mode. Note
that the keys’ illumination indicates current Zone status at
all times.
The rotary control is not used in this function.
Once a Zone has been enabled, pressing the ZONE button
twice on the CDR-1(s) in the Zone will bring up the Enter
Key request (see note below).
Zone
i
+
h
-
Enter Key
When the CDR‑1 key has been entered, the rst EQ
adjustment screen (Treble) opens. Adjustment of HF EQ
can be made with the + and buttons. The available range is
±14dB, in 2dB steps.
CDR Zone Setup
Zone 1
Stereo X
Edit Input Label
Input 1
Edit Zone Label
Zone 1
Edit Group Label
Group 1
Set Key
1234
RS232 Baud Rate
9600
RS232 Flow
No Flow
Power Up Mode
Factory
Save Defaults
X
Update Firmware
X
Reset Mixer
System Menu Flow Diagram