User Manual
The battery inside this product is a sealed lead-acid battery. It is required by law to
be removed and recycled or disposed of properly. While there are federal regulations
thatmustbecompliedwiththroughouttheUnitedStates,yourindividualstateorlocal
governments may have additional regulations to be followed.
When the battery in this product is in need of replacement, remove it according to the
instructions provided below and take it to your local recycling center for proper recycling
or disposal. If you don’t have a local recycling center that handles sealed lead-acid
batteries, contact your local environmental agency for instructions.
Removal instructions:
Beginbymakingsurethatbothclampsaresecurelyplacedinapositionthatensures
they will not come into contact with each other.
1.Ensuretheunit’sON/OFFswitchisintheOFFposition.
2. LaytheJump-N-Carrydownonitsfront.Onthebackoftheunit,locatethe
screws that hold the case together (including screws located in the cable
management tracks).
3. Remove the screws, then lift off the back half of the case, lifting first from the
bottom.
4. Onthetopofthebatteryaretwoterminals,eachwithwiresconnectedtothem.
Disconnect these wires from the battery by removing the bolts that hold them to
the battery terminals. To prevent accidental arcing, be careful not to touch both
battery terminals with the tools being used to remove the bolts.
5. Liftthebatteryoutofthefronthalfofthecase.
Battery Replacement and Disposal
Pb
This unit contains a sealed non-spillable lead-acid battery.
This battery must be recycled. Consult your state or local
government concerning regulations for proper disposal.