Clock-User Manual-2020

5 | Clock Multi Manual
Stove Performance Results
All efciencies in table are Net value.
Parameter Large
Blitheld
Standard
Blitheld
Compact
Blitheld
Double
Blitheld
Test duration h 1.01 1 1.05 1
Total efciency % 78.5 77.8 79.9 78
Nominal heat
output
kW 8.2 5 5.0 10.6
Approximate
Output range
KW 6-10 3.5-9.5 3.5-7 8-14kw
Mean CO
emission (at 13
% O2)
% 0.05 0.08 0.06 0.11
Mean ue gas
temperature
ºC 313 288 279 327
Flue gas mass
ow
g/s 5.7 4.1 3.5 7.7
Mean CnHm
emission (at 13
% O2)
Nmg/
m3
44 10 50 79
Mean NOx
emission (at 13
% O2)
Nmg/
m3
116 107 147 65
DIN Plus
particulates (at
13 % O2)
Nmg/
m3
14 9 21 17
Smokeless