Welcome to your stove All our stoves are hand made in the uk from the start to finish a claim only few can make. Please note it is a legal requirement under England wales and European building regulations that the installation of the stove carried out under local authority building control approval or installed by a competent person registered with a government approved scheme. This appliance does get hot whilst running.
Stove Performance Results All efficiencies in table are Net value. Wood Parameter Large Blithfield Standard Blithfield Compact Blithfield Double Blithfield Contemporary Brocksford Test duration h 0.75 0.86 0.85 0.75 0.75 Total efficiency % 78.8 84.3 82.3 75.3 81.53 Nominal heat output kW 8 5 5 10.5 4.77 Approximate Output range KW 6.5-10 3.5-9 3.5 -7 8-12 3.5-7 Mean CO emission (at 13 % O2) % 0.10 0.11 0.07 0.08 0.
Stove Performance Results All efficiencies in table are Net value. Smokeless Parameter Large Blithfield Standard Blithfield Compact Blithfield Double Blithfield Test duration h 1.01 1 1.05 1 Total efficiency % 78.5 77.8 79.9 78 Nominal heat output kW 8.2 5 5.0 10.6 Approximate Output range KW 6-10 3.5-9.5 3.5-7 8-14kw Mean CO emission (at 13 % O2) % 0.05 0.08 0.06 0.11 Mean flue gas temperature ÂșC 313 288 279 327 Flue gas mass flow g/s 5.7 4.1 3.5 7.
Pre-Installation This appliance must be fitted in accordance with the current Building Regulations and by competent registered person. Health and Safety Precautions Special care must be taken when installing the stove that the requirements of the Health and Safety at Work Act are met. Note: This appliance is heavy and must be handled with care. Adequate facilities must be available for loading, unloading and site handling. The appliance is supplied fully assembled for a top flue arrangement.
Installation CO Alarms In addition to these instructions the requirements of BS 8303 and BS EN 15287 must be fulfilled. Local Authority Bylaws and Building Regulations regarding the installation of Solid Fuel burning appliances, flues and chimneys must also be taken into account.
Commissioning Check all internal parts are fitted correctly. There are no gaps between the firebricks and baffle and the log retainer is secure. Check the Ash pan, 15mm steel grate, Log retainer, Firebricks: rear and sides and baffle are all fitted correctly. Check all the levers are operating fully and freely.
Important Information for Wood Burning With a full load of wood and burning near nominal output the stove will need to be refuelled approximately every 1-1.5 hours. (One or two large logs will burn longer than a number of smaller ones). Wood can usually be stacked higher in the stove than solid mineral fuel but care must be taken that logs do not touch the baffle or the glass panel. Do not stack logs above the level of the tertiary air inlet in the rear ceramic firebox liners at the back of the stove.
Cleaning Warranty Glass: Despite the advanced air wash system provided, the glass will still need cleaning from time to time depending on the fuel quality and burning rates used. Never clean glass when the stove is hot. Always use stove glass cleaner or ceramic hob cleaner, which is available from your stove retailer or supermarket. As an alternative, use a wet cloth with some of the wood ash if burning wood but be very careful to use very clean ash so as not to scratch the glass.
Dimensions of the range of stoves Contemporary 5kw Brocksford Large 8kw Blithfield Standard 5kw Blithfield Compact 5kw Blithfield Double sided Blithfield Stove Contemporary 5 kw Brocksford Large 8kw Blithfield Standard 5kw Blithfield Compact 5kw Blithfield Double 10kw Blithfield Height 970 640 600mm (1075mm) 600 600 Width 480 590 525 430 535 Depth 430 390 390 335 600 Flue collar Height n/a 680 655mm (1125mm) 655 655 FC back to centre 150 100 90mm 90 300 Flue collar
Stove options available Stove Contemporary 10 kw Brocksford Large 8kw Blithfield Standard 5kw Blithfield (cook model) Compact 5kw Blithfield Double 10kw Blithfield NA Y Y Y N Rear exit Y N N N N Outside air kit Y Y Y Y Y Brass Handle N Y Y Y Y Stove colour Y Y Y Y Y NA Y Y Y Y Heat shield Log box (Please note these are charged as extra items and may have lead times) DEFRA Settings Settings for the 8kw,5kw and 5kw compact versions. Open to engage Defra stop.
Double sided stove Undo grub screw to engage Defra stop.
Wood burning The right hand dial is the primary and the left hand dial is secondary (air wash) to open these turn clock wise and to close turn anti clock wise When starting the fire open the secondary control to open to maximum and the primary open if needed. After about 20-25 min the stove will be up to temperature. Then Shut the right hand dial (primary) and control with the secondary (air wash) Solid fuel When starting the fire open both the primary & secondary controls to maximum.
| Clock Multi Manual
IMPORTANT INSTALLATION NOTE Before installing this appliance please make a note of the serial number as this is needed for the online warranty registration. Serial numbers are on the data plate at the back or base of all stoves. The Blithfield 5, Compact and 8kw models have the data plate on the rear panel (top left as you look at the stove). The Double Sided has the date plate underneath and the Brocksford data plate is inside the log store at the base of the stove.