Technical information

Clipsal Product Catalogue
75
S2000 Universal Tactile Dimmers
Dimmer
To open programming press the switch 10
times. All lights will dim.
a. Programming scenes
• Presstheswitch2times.Youarenowin
‘Scene Setting One’. Dim or brighten the
lights to the require level.
• Presstheswitch3times–thisis‘Scene
Setting Two’. Dim or brighten the lights to
the required level.
• Presstheswitch4timesfor‘SceneSetting
Three’. Dim or brighten the lights to the
required level.
• Presstheswitch5timesfor‘SceneSetting
Four’. Dim or brighten the lights to the
required level.
• Closeprogrammingmode,orproceedto6b.
for inter-scene fade rate settings.
• Tocloseprogramming,presstheswitch10
times. All lights will brighten.
b. Programming Inter-Scene Fade Rates
This section of programming controls the
rate of change between scenes.
• Openprogrammingmodeifitwasclosed
after completing 6a.
• Presstheswitch6times.
Adjust light dimming on the master switch as
follows:
• Minimumlightlevelgivesa0.2secondFade
Rate.
• Maximumlightlevelgivesan18second
Rate, i.e. for the 18 second Fade Rate
brighten the lights to 100%
• Lightlevelsbetweenminimumand
maximum will be pro-rata of the 18 seconds,
for example 50% light = 9 seconds Fade
Rate.
• Closeprogrammingasin6a,orproceedto
O-Time Fade Rate Setting.
The system is now re-programmed and can
be used as normal.
c. O Time Fade Rate
This controls the rate at which the light
switches o.
• Openprogrammingmodeifitisclosed.
• Presstheswitch7times.Adjustlight
dimming on the Master Switch as follows:
• Minimumlightlevelisa1.5secondO
Rate.
• Maximumlightintensitygivesan11
minute O Rate.
• LightlevelsbetweenMinimumand
Maximum will be pro-rata of the 11 minute
O Fade Rate, for example 50% light level
= 51/2 minute O Fade Rate.
• Closeprogrammingmode
The system is now re-programmed and can
be used as normal
500VA UNIVERSAL DIMMER (1760502)
12V
LOW-VOLTAGE
240V
DOWN LIGHTER
240V
INCANDESCENT
MINIMUM
NO OF
LAMPS
MAXIMUM
NO OF
LAMPS
MINIMUM
NO OF
LAMPS
MAXIMUM
NO OF
LAMPS
MINIMUM
NO OF
LAMPS
MAXIMUM
NO OF
LAMPS
20W 35W 50W 20W 35W 50W 50W 50W 20W 40W 60W 100W 20W 40W 60W 100W
1 1 1 25 14 10 1 10 1 1 1 1 25 12 8 10
800W UNIVERSAL DIMMER (1760802)
12V
LOW-VOLTAGE
240V
DOWN LIGHTER
240V
INCANDESCENT
MINIMUM
NO OF
LAMPS
MAXIMUM
NO OF
LAMPS
MINIMUM
NO OF
LAMPS
MAXIMUM
NO OF
LAMPS
MINIMUM
NO OF
LAMPS
MAXIMUM
NO OF
LAMPS
20W 35W 50W 20W 35W 50W 50W 50W 20W 40W 60W 100W 20W 40W 60W 100W
1 1 1 40 22 16 1 16 1 1 1 1 40 20 13 8
6. Load Tables
7. Programming Instructions